GAS SPECIFICATIONS
PROPANE (LP)
Gas Supply and Pressure
TRADITIONAL SERIES MODELS
EN 437 Gas Group
|
3+
|
3B/P
|
3B/P
|
3P
Inlet Pressure (mbar)
28-30/37/50
*
30/37
*
50
*
30/37/50
*
Declared Input (kW)
|
3+
|
3B/P
|
3B/P
|
3P
TS-5-RFG-CE-LP
27.5
33.6
33.6
27.5
TS-5-RFG-IR-CE-LP
46.6
57
57
46.6
TS-6-RFG-CE-LP
27.5
33.6
33.6
27.5
TS-6-RFG-IR-CE-LP
46.6
57
57
46.6
Factory Specified
Pressures at Gas Valve
Outlet (mbar)
|
3+
|
3B/P
|
3B/P
|
3P
SV-1 SV-2
SV-1 SV-2 SV-1 SV-2 SV-1 SV-2
TS-5-RFG-CE-LP
-
15.6
-
15.6
-
15.6
-
20
TS-5-RFG-IR-CE-LP
17.5
15.6
17.5 15.6
17.5 15.6
22.4
20
TS-6-RFG-CE-LP
-
15.6
-
15.6
-
15.6
-
20
TS-6-RFG-IR-CE-LP
17.5
15.6
17.5 15.6
17.5 15.6
22.4
20
Propane (LP): Maximum inlet gas pressure to the oven, after the external regulator (if used),
must not exceed 34 mbar (14" W.C. or 1/2 psi)
SCOPE OF APPROVALS
G31 @ 37 mbar
*
- I
3P(37)
-
BE, CH, CZ, ES, FR, GB, GR, HR, IE, IT, LT, NL, PL, PT, SI, SK, TR
G31 @ 50 mbar
*
- I
3P(50)
-
AT, BE, CH, CZ, DE, ES, FR, GB, NL, SK
G30 @ 28-30 mbar, 37 mbar
*
- I
3+(28-30/37)
-
BE, CH, CY, CZ, ES, FR, GB, GR, IE, IT, LT, PT, SI, SK, TR
G30 @ 30 mbar - I
3B/P(30)
-
AT, BE, CY, CZ, DE, DK, EE, FR, GB, HR, HU, IT, LT, NL, NO, PL, RO, SE, SI, SK
G30 @ 50 mbar
*
- I
3B/P(50)
-
AT, CH, CY, CZ, DE, FR, SK