PG
13
OF
36
M0324.00 APRIL 2020
Traditional Series CE
Installation and Operation Manual
GAS SPECIFICATIONS
Natural Gas (NG): Maximum inlet gas pressure must not exceed 34 mbar (14" W.C. or 1/2 psi)
SCOPE OF APPROVALS
G20/G25.3 @ 20/25 mbar - I
2EK(20)
-
NL
G20 @ 20 mbar - I
2H(20)
-
AT, CH, CZ, DK, EE, ES, FI, GB, GR, HR, HU, IE, IT, LT, LV, NO, PT, RO, SE, SI, SK and TR
G20 @ 20 mbar - I
2HS(20)
-
HU
G20 @ 20 mbar - I
2ELL
-
DE
G20/25 @ 20/25 mbar - I
2E+
-
BE and FR
TRADITIONAL SERIES MODELS
EN 437 Gas Group
|
2H
|
2L
|
2HS
|
2ELL
|
2EK
Inlet Pressure (mbar)
20
25
25
20
20/25
Declared Input (kW)
|
2H
|
2L
|
2HS
|
2ELL
|
2EK
TS-5-RFG-CE-NG
30.8
30.8
30.8
30.8
26.3
TS-5-RFG-IR-CE-NG
55.1
55.1
55.1
55.1
47
TS-6-RFG-CE-NG
30.8
30.8
30.8
30.8
26.3
TS-6-RFG-IR-CE-NG
55.1
55.1
55.1
55.1
47
Factory Specified
Pressures at Gas Valve
Outlet (mbar)
|
2H
|
2L
|
2HS
|
2ELL
|
2EK
SV-1 SV-2 SV-1 SV-2
SV-1 SV-2 SV-1 SV-2 SV-1 SV-2
TS-5-RFG-CE-NG
-
11.8
-
11.8
-
11.8
-
11.8
-
11.8
TS-5-RFG-IR-CE-NG
8.7 11.8
8.7 11.8
8.7 11.8
8.7 11.8
8.7 11.8
TS-6-RFG-CE-NG
-
11.8
-
11.8
-
11.8
-
11.8
-
11.8
TS-6-RFG-IR-CE-NG
8.7 11.8
8.7 11.8
8.7 11.8
8.7 11.8
8.7 11.8
NATURAL GAS (NG)
Gas Supply and Pressure