An ongoing program of product improvement may require us to change
specifications without notice.
WS-MS-(4, 5, 6, 7)-W-IR,
Revised May 2015. Doc no: M0036.04
7
Mountain Series
Installation and Operation Manual
or visit
woodstone-corp.com
Wood Stone Corporation
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
Toll Free 800.988.8103
Tel 360.650.1111
Fax 360.650.1166
INSTALLATION CLEARANCES
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL THE OVEN. FAILURE TO FOLLOW
INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. CONTACT YOUR
LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR
AREA.
!
WARNING:
Installation and servicing of this product could expose you to glasswool/
ceramic fibers as well as Calcium Silicate dust. ALWAYS WEAR RESPIRATORY AND EYE
PROTECTION WHEN INSTALLING OR SERVICING THIS APPLIANCE. Please read this entire
manual before you install the oven. Failure to follow instructions may result in property
damage, bodily injury or even death. Contact your local building or fire officials about
restrictions and installation inspection in your area.
CLEARANCES
1.
The Wood Stone gas-fired oven must have a
minimum 1" clearance to combustibles from all sides, and 14"
clearance to combustibles from the top
(see INSTALLATION CLEARANCES section on next page)� If building a
facade that will contact the oven, use completely non-combustible materials*� Please note that standard Drywall (or
Sheetrock) is considered a combustible�
2.
Any facade materials 6" to either side of the oven doorway and above must be constructed of non-combustible
building materials�
3.
Install this oven only on a non-combustible floor surface� (Cet appareil doit être installé sur une surface de
plancher non-combustible�) The non-combustible floor surface should extend 36" out in front of the oven, and
extend 30" to either side of the oven doorway�
*When non-combustible building materials contact the body of the appliance, the clearances to combustibles are
transferred to those non-combustibles�
NOTICE:
For stucco-ready appliances (model numbers ending in “-S”), the same clearances as described above apply�
Non-combustible stucco mix must be used and applied to a minimum thickness of 1"�
IF THIS OVEN IS NOT PROPERLY INSTALLED A FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW
THESE INSTALLATION INSTRUCTIONS. A MAJOR CAUSE OF OVEN RELATED FIRES IS FAILURE TO MAINTAIN
REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF UTMOST IMPORTANCE THAT
THIS OVEN BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.
WARNING:
DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIAL.
Summary of Contents for MT. ADAMS WS-MS-5-W-IR