PG
13
OF
34
M0202.09 JULY 2020
Wood Stone Gas Plancha (GPL)
Installation and Operation Manual
UTILITY SPECIFICATIONS
If you must convert the Plancha to run on a different gas type, i�e� NG to LP,
please contact Wood Stone to obtain the necessary parts and instructions�
No modification is required for use at high altitudes.
GAS INFORMATION
BURNER MANIFOLD PRESSURE
Model
Natural Gas (NG) model
Propane (LP) model
WS-GPL-6036-CT01
WS-GPL-4836-CT01
WS-GPL-3636-CT01
WS-GPL-2436-CT01
BTU/HR INPUT RATE
Model
Natural Gas (NG) model
Propane (LP) model
WS-GPL-6036-CT01
150,000 BTU/hr
150,000 BTU/hr
WS-GPL-4836-CT01
110,000 BTU/hr
118,000 BTU/hr
WS-GPL-3636-CT01
85,000 BTU/hr
85,000 BTU/hr
WS-GPL-2436-CT01
60,000 BTU/hr
60,000 BTU/hr
MINUMUM INCOMING GAS PRESSURE
Model
Natural Gas (NG) model
Propane (LP) model
WS-GPL-6036-CT01
WS-GPL-4836-CT01
WS-GPL-3636-CT01
WS-GPL-2436-CT01
ELECTRICAL RATINGS
Model
Voltage
Amperage
WS-GPL-6036-CT01
120 VAC
0�7 A
WS-GPL-4836-CT01
120 VAC
0�7 A
WS-GPL-3636-CT01
120 VAC
0�6 A
WS-GPL-2436-CT01
120 VAC
0�4 A
The Plancha is equipped with a NEMA 5-15P plug for use with a standard 120 VAC 15 A or 20 A outlet�
Electrical Grounding:
This appliance must be electrically grounded in accordance with local codes, or in the absence of local
codes, with the National Electrical code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22�1 as applicable�
ELECTRICAL SUPPLY CORD AND GAS CONNECTION SHOULD BE ROUTED SO THAT THEY ARE NOT SUBJECTED TO THE
HEAT COMING FROM THE PLANCHA COOKING SURFACE.
The Plancha is equipped with a gas pressure
regulator that is preset at the factory� This
regulator comes installed on the rear of the
unit� If incoming gas pressure is less than 1/2
psi (14 inches W�C�), no additional regulator
is required or recommended� If incoming gas
pressure is greater than 1/2 psi (14 inches
W�C�), an additional regulator, by others,
must be installed on the gas line serving the
appliance� Do not remove the factory supplied
regulator�
The Wood Stone Gas Plancha is equipped
with a 3/4 inch FNPT gas connection
located at the rear of the appliance� The
installer should provide an appropriate quick
disconnect fitting for connection to the gas
supply�
5�0" W�C�
10�0" W�C�
9�0" W�C�
4�0" W�C�