![Wood-mizer SLAB-MIZER MB200AF Installation Manual Download Page 9](http://html1.mh-extra.com/html/wood-mizer/slab-mizer-mb200af/slab-mizer-mb200af_installation-manual_994586009.webp)
SLAB-MIZER AUTO FEED INSTALLATION
Form 2452
9 of 18
Publication 2/17/21
13.
Put wire from
8 Gray
terminal block to small feed motor VFD LI2
14.
Remove
brown wire
from cross feed relay A1 and put in
9 Blue
terminal block.
15.
Put wire from
9 Blue
terminal block to cross feed relay A1
16.
Use the #10-24 screws, washer, and nuts to mount the terminal block to the right-hand
inside wall of the control box door, using the holes previously drilled.
FIG. 10