Simple Set PID Settings
WMdoc122320
8-3
8
See Figure 8-2.
4.
Press the Auto
button several times until "Gear: 0.xxxx" appears.
5.
Use the Up
/Down
buttons to set the value of the Gear Setting as shown in the
table below.
6.
Press the Auto
button to display "InvGear: xx".
7.
Use the Up
/Down
buttons to set the InvGear setting to the required value as
shown in the table above.
8.
Press the Manual
button to return to the main menu.
Simple Set PID Settings
1.
Make sure the power to the control box is on.
2.
Press and hold the Manual
button and then press and hold the UP
button.
FIG. 8-2
Models
Revision
Gear Setting
InvGear Setting
LT40 (Default)
All
0.0938 (Default)
No (Default)
LT35/LT35HD
A5.00+ (or any revision upgraded
with Up/Down Kit 074316)
0.1170
No
LX150
A1.00+
0.1350
Yes
TABLE 8-0
3H1128
Scroll Up/Down
Display
Manual
Auto