Troubleshooting Guide
Power Feed Preliminary Test
Troubleshooting Guide
50HD07doc072310
6-18
6
6.8
Power Feed Preliminary Test
This test will determine if the problem is mechanical or electrical.
1.
Remove the drive belt from the power feed drive pulley.
2.
Turn the key switch to the ACC position. Put the carriage forward/reverse switch into the
forward position and turn the feed rate dial through all speeds. If the power feed motor
runs properly at all speeds, the problem is a mechanical one instead of an electrical one.