![Wood-mizer LT40L DH Maintenance Manual Download Page 71](http://html1.mh-extra.com/html/wood-mizer/lt40l-dh/lt40l-dh_maintenance-manual_994654071.webp)
Maintenance
Vertical Mast Rails
Maintenance
HDSdoc041118
3-4
3
3.5
Vertical Mast Rails
Clean and lubricate the vertical mast rails every 50 hours of operation. Clean with solvent
and remove any rust with a light-grade sand paper or emery cloth. Lubricate the mast with
motor oil or automatic transmission fluid (ATF).
CAUTION!
Never use grease on the mast rails as it will
collect sawdust.
3.6
Drum Switches
Lubricate the up/down and power feed drum switch contacts inside the control panel
every fifty hours of operation. Use only contact grease supplied by Wood-Mizer. Remove
the control panel cover. Use a cotton swab to apply grease to the switch contact ends.
WARNING!
Drum switch grease contains Petroleum
Hydrocarbon Lubricant. Eye and skin irritant. If introduced
into eyes, flush with water for at least 15 minutes. If film or
irritation persists, seek medical attention. Wash skin with
soap and water. If ingested, do not induce vomiting
- contact a physician. KEEP OUT OF THE REACH OF
CHILDREN.
50
50