Setup & Operation
Sawmill Setup
Setup & Operation
15doc080113
3-1
3
SECTION 3 SETUP & OPERATION
3.1
Sawmill Setup
IMPORTANT!
Before starting to use the sawmill you have to meet the
following conditions:
Set up the sawmill on firm, level ground and level the sawmill. Secure the sawmill to the
ground to prevent moving during operation. A concrete foundation or pads (rated to support
31 T/m
2
at each sawmill foot position) and 16mm anchored bolts are recommended.
Under roof, the sawmill should always be operated with the sawdust collection system.
The sawmill can be operated under roof only.
The sawmill can be operated in temperature range from -15
o
C to 40
o
C only.
The illumination at the operator's position should be at least 300lx.
The sawmill operator’s position is shown below.
Have a qualified electrician install the power supply (according to EN 60204 Standard).
The power supply must meet the specifications given in the table below.
IMPORTANT!
When starting the machine for the first time, check that
main motor rotation direction is as indicated by the arrow located on
the motor body (fan guard). If the rotation direction is incorrect, invert
the phases in the phase inverter in the power socket (electric box).
Setting the phases in the phase inverter correctly will ensure correct
rotation directions of all sawmill motors.
3-Phase
Volts
Fuse disconnect
Suggested Wire Size
400 VAC
16 A
2,5 mm
2
to 15m length
TABLE 3-0
!