MULTISETWORKS OPERATION (OPTIONAL EQUIPMENT)
Errors
3
3-22
Multisetworkdoc012819
MULTISETWORKS OPERATION
connecting with PLC 2.0 controller; encoders of the saw head number 5 and 6 are connecting with PLC 3.0
controller).
Controller/Module
Encoder/Saw Head
Inputs
PLC 1.0
Encoder 1/Saw Head 1
I0 and I1
PLC 1.0
Encoder 2/Saw Head 2
I4 and I5
PLC 2.0
Encoder 3/Saw Head 3
I0 and I1
PLC 2.0
Encoder 4/Saw Head 4
I6 and I7
PLC 3.0
Encoder 5/Saw Head 5
I0 and I1
PLC 3.0
Encoder 6/Saw Head 6
I6 and I7
TABLE 3-1