MAINTENANCE
Safety Devices Inspection
6
6-14
1597doc030112
MAINTENANCE
MP150E5S Moulder – Safety Devices Inspection
Safety devices on the machine which must be checked before every shift:
E-STOP button and its circuit inspection
Green safety button inspection
Inspection of the control circuits with the E-STOP button pressed
Cutter cover safety switch and its circuit inspection.
1. E-STOP button and its circuit inspection
Press and hold the green safety button;
Turn on the cutter motor;
Press the E-STOP button located on the left side of the control box. The cutter motor should
be stopped. Pressing the START button should not start the motor until the E-STOP button is
released.
2. Green safety button inspection
Be sure the E-STOP button is released;
Press and hold the green safety button;
Turn on the moulder motor. The motor should be started;
WMM087
Emergency
Stop
Safety
Button
Motor Start
Button
Power Feed
Switch
Up/Down System
Button