WOODMASTER OUTDOOR FURNACES • OWNER'S MANUAL
Parameter Description and Factory Settings:
• Set (set point) - 170°F
• Hy (Differential) - 10°F
• ALL (Low Alarm) - 120°F
How To:
• View Set Point — Push and immediately release the set key, display
will indicate set point and will return to water temperature after 5
seconds.
• Change the Set Point — Push and hold the set key until the set point
is displayed, change the value using the up and down arrows, and
press the set key. The set point will flash a few times and then the
display will return to water temperature.
• Change Hy or ALL — Push and hold the set and down arrow keys
at the same time until HY is displayed. Using the up and down
arrows, select the parameter to be changed (Hy or ALL), push the
set key once (value of parameter should be displayed), use arrows
to change value, and push the set key (value should flash a few
times). After 10-15 seconds the display will change back to water
temperature.
Green Float Light:
• Green light ON: Water level OK.
• Green light OFF: Water level low, add water through vent pipe or
follow fill valve instructions if system is installed with an indoor fill
valve.
Light Switch:
• Operates light.
Fan Switch:
• The fan switch must be on during normal operation, but may be
turned off to fill furnace or for maintenance.
ETC Reference
1. GENERAL WARNING
1.1 PLEASE READ BEFORE USING THIS MANUAL
• This manual is part of the product and should be kept near the
instrument for easy and quick reference.
• The instrument shall not be used for purposes different from those
described hereunder. It cannot be used as a safety device.
• Check the application limits before proceeding.