![Wood and Douglas 1335 Operating Instructions Manual Download Page 91](http://html.mh-extra.com/html/wood-and-douglas/1335/1335_operating-instructions-manual_994266091.webp)
Wood & Douglas Ltd, Lattice House
© Wood & Douglas Ltd 2009
Baughurst, Tadley, Hants, RG26 5LP
Tel:+44 (0)118 981 1444 Fax: +44 (0)118 981 1567
email: [email protected]
website: www.woodanddouglas.co.uk
1892 1335 - Orion Radio Modem Operating Instructions - v2.9 / Aug 2009
91
Notes:
This adaptor converts all four digital outputs to floating SPDT relay contacts.
The Alert output is a relay or open-collector output, depending on how the unit
was ordered, and is not converted.
If the Alert output is to be used, and is an open collector output, the 0V return is via PL1.
If LED indication is required when an output is in its energised state, 12V at up to 40mA must
be provided via connector PL1, which may be taken from the same supply as the Orion.
LEDs are labelled to indicate which port they refer to.
PL1 connections are:
pin 1 : 12V DC
pin 2 : 0V
Accessories
An accessory kit containing these two adaptors, a power supply and a programming cable
for the Orion is available as part number 01142 1100 A.
Orion Mounting Adaptor
An adaptor which enables the Orion to be mounted on a DIN rail is available as part number
???.
Summary of Contents for 1335
Page 2: ...2 1892 1335 Orion Radio Modem Operating Instructions v2 9 Aug 2009 ...
Page 7: ...1892 1335 Orion Radio Modem Operating Instructions v2 9 Aug 2009 7 Part One the Orion Unit ...
Page 8: ...8 1892 1335 Orion Radio Modem Operating Instructions v2 9 Aug 2009 ...
Page 40: ...40 1892 1335 Orion Radio Modem Operating Instructions v2 9 Aug 2009 ...
Page 61: ...1892 1335 Orion Radio Modem Operating Instructions v2 9 Aug 2009 61 Part Three Appendices ...
Page 62: ...62 1892 1335 Orion Radio Modem Operating Instructions v2 9 Aug 2009 ...