On Screen Display Menu 

On Screen Display Menu 

② 

 TOUR  

The  T our function consists of several presets which  r un in sequence. Also, the moving 
speed(0~63 step) and dwell time (1~99sec) is adjustable. There are 1 to 8 programmable  T our functions.  

¢¹ 

-------------------- 

-------------------- 

-------------------------- 

----------------------------- 

-------------------- 

TOUR SELECT 

TOUR EDIT 

 S A VE   CLR    BACK   EXIT 

< NEAR/RIGHT   ¢¹  TOUR NO    > 

TOUR MENU 

T01   02   03   04   05   06 

  07   08   

< SEL ¢¹ NEAR / MOVE ¡æ J O YSTICK > 

L ABEL :  

< STORE  ¢¹  TELE   MOVE  ¢¹  J O Y  > 

< DEL    ¢¹  WIDE   BACK  ¢¹  NEAR > 

TOUR  L ABEL EDIT <01> 

NO   PRESET   SPEED   DWELL 

01    <XX>       XX          XX  

02       XX          XX          XX  

03       XX          XX          XX 

04       XX          XX          XX  

05       XX          XX          XX 

06       XX          XX          XX 

07       XX          XX          XX  

08       XX          XX          XX 

< SEL ¢¹ NEAR    PRESET ¡æ LE F T > 

TOUR EDDIT <01> 

 01  02  03  04  05  06  07 

 08  09  10  11  12  13  14 

 15  16  17  18  19  20  21 

 22  23  24  25  26  27  28 

 29  30  31  32  33  34  35 

 36  37  38  39  40  41  42 

 43  44  45  46  47  48  49 

 50  51  52  53  54  55  56 

 57  58  59  60  61  62  63  

< SEL ¢¹ NEAR / MOVE ¡æ J O YSTICK > 

PRESET SELECT 

③ 

 SCAN  

The Scan function keeps panning between two programmed pan positions. Also the moving  
speed(1~64 step) is adjustable. There are 4 programmable Scan functions.  

------------------------- 

--------------------------- 

----------------------------- 

-------------------- 

L ABEL :  

< STORE  ¢¹  TELE   MOVE  ¢¹  J O Y  > 

< DEL    ¢¹  WIDE   BACK  ¢¹  NEAR > 

¢¹ 

-------------------- 

 S A VE   CLR    BACK   EXIT 

< NEAR/RIGHT   ¢¹  SCAN NO    > 

SCAN MENU 

SCAN  L ABEL EDIT <01> 

S01   02   03   04  

< SEL ¢¹ NEAR / MOVE ¡æ J O YSTICK > 

SCAN SELECT 

 POSITION   :  359.9, -45.0 

<  EXIT   ¢¹   FOCUS NEAR    > 

SCAN S T A R T POSITION 

 POSITION   :  359.9 

<  EXIT   ¢¹   FOCUS NEAR    > 

SCAN END POSITION 

④ 

  P A T TERN   

The  P atte r n function memorizes the user's random moving path and zoom ratio. There are four  
programmable  P atte r n functions. And the recording time limit is 60 seconds for each. 

¢¹ 

-------------------- 

-------------------- 

-------------------------- 

----------------------------- 

-------------------- 

 S A VE   CLR    BACK   EXIT 

< SEL ¢¹ NEAR / MOVE ¡æ J O YSTICK > 

L ABEL :  

< STORE  ¢¹  TELE   MOVE  ¢¹  J O Y  > 

< DEL    ¢¹  WIDE   BACK  ¢¹  NEAR > 

⑤ 

 AREA  

The Area function is that display the Area name between two programmed pan positions.  
There are 4 programmable Area display functions.   

¢¹ 

-------------------- 

---------------------------------- 

---------------------------------- 

----------------------------- 

-------------------- 

 S A VE   CLR    BACK   EXIT 

L ABEL :  

< STORE  ¢¹  TELE   MOVE  ¢¹  J O Y  > 

< DEL    ¢¹  WIDE   BACK  ¢¹  NEAR > 

AREA  L ABEL EDIT <01> 

A01   02   03   04  

S01   02   03   04  

< SEL ¢¹ NEAR / MOVE ¡æ J O YSTICK > 

 POSITION   :  359.9 

<  EXIT   ¢¹   FOCUS NEAR    > 

 POSITION   :  000.0 

<  EXIT   ¢¹   FOCUS NEAR    > 

RECORD 

P L A Y 

< NEAR/RIGHT   ¢¹   P A T T NO    > 

P A T TERN  MENU 

P A T TERN  SELECT 

P A T TERN  L ABEL EDIT <01> 

||||       03/60 

EXIT  ¢¹  NEAR     216.0, -00.8 

P A T TERN  RECORD 

||||       03/20 

EXIT  ¢¹  NEAR     215.8, -00.8 

P A T TERN  P L A Y 

< NEAR/RIGHT   ¢¹  AREA NO    > 

AREA MENU 

AREA SELECT 

AREA S T A R T  P AN POSITION 

AREA STOP  P AN POSITION 

14    

MIN PTZ CAMERA 

15    

MIN PTZ CAMERA 

¢¹ 

¢¹ 

¢¹ 

¢¹ 

Summary of Contents for PS-100N

Page 1: ...TZ DOME CAMERA PS 100N PS 100P Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use W 388058120 PRINTED IN KOREA Distribute...

Page 2: ...en tested and found to comply with limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when...

Page 3: ...consisting of presets with individual dwell time Pattern Up to 4 programmable Patterns memorized the PTZ movement Area Up to 4 programmable Area display set Privacy zone masking Up to 4 programmable...

Page 4: ...s 1 loose proof screw In ceiling Mount To install and use the PS 100 the followings should be needed NOT included in box 1 Power adaptor Over 1A The power adaptor should have capacity over 1 Ampere Lo...

Page 5: ...ded in the camera box The Video and RS 485 control cables Power adaptor over 1A and installation tools are necessary to complete the installation For cable connection make a hole Hole size 70mm in the...

Page 6: ...85 control cables Power adaptor over 1A and installation tools are necessary to complete the installation For cable connection make a hole Hole size 110mm in the ceiling where you want to install the...

Page 7: ...en Display Menu INITIALIZE When you turn on the power the INITIALIZE screen on the monitor will appear During Initialization you can check the PTZ information If the information is different with your...

Page 8: ...LABEL STORE TELE MOVE JOY DEL WIDE BACK NEAR SAVE CLR BACK EXIT NEAR RIGHT SCAN NO SCAN MENU SCAN LABEL EDIT 01 S01 02 03 04 SEL NEAR MOVE JOYSTICK SCAN SELECT POSITION 359 9 45 0 EXIT FOCUS NEAR SCA...

Page 9: ...BEL EDIT 01 In the Privacy Position setup the masking size can be variable with the iris OPEN CLOSE key OPEN make the mask larger CLOSE make the mask smaller TITLE You can set the camera title and it...

Page 10: ...crease or decrease the Red or Blue values to shift the color of the object Red Red Gain can be changed Blue Blue Gain can be changed You can set the camera exposure a Brightness The brightness of the...

Page 11: ...mode to distinguish dark images clearly IRIS SET You can set the Iris mode Auto The brightness of the image signal can be adjusted automatically depending on the amount of light Manual The brightness...

Page 12: ...tation Speed Flip Lens Initialization Focus Control Iris Control Protocols Communication Power Consumption Operating Temperature Operating Humidity Certification Dimensions Weight QUICK COMMAND FUNCTI...

Reviews: