Wonwoo PS-100N Installation & Operating Manual Download Page 2

USER INFORMATION 

02   

MIN PTZ CAMERA

03   

MIN PTZ CAMERA

CONTENTS

3p.

4p.

5p.

6p.

6p.

6p. 

7p.

9p.

12p.

13p.

13p.

14p.

14p.

15p.

15p.

16p.

16p.

17p.

18p.

19p.

19p.

21p.

22p.

23p.

1. USER INFORMATION 
2. FEATURES
3. PRECAUTIONS
4. PTZ SETTING & INSTALLATION 

      Unpacking 

      Preparation for installation

      PTZ DIP switch setup

      Installation & Cable connection

5. ON SCREEN DISPLAY MENU

      Motion menu

               Preset

               Tour

               Scan

               Pattern

               Area

               Alarm

               Privacy 

      Dome menu

      Camera menu

      Clear menu

      PTZ reset

6. DIMENSIONS
7. SPECIFICATIONS
8. QUICK COMMAND

The lightning flash with an arrowhead symbol, within an equilateral triangle is 
intended to alert the user to the presence of uninsulated "dangerous voltage" 
within the product's enclosure that may be of sufficient magnitude to constitute 
a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to 
the presence of important operating and maintenance (servicing) instructions in the
literature accompanying the appliance.

FCC COMPLIANCE STATEMENT

INFORMATION

-This equipment has been tested and found to comply with limits for a Class A

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instruction manual, may cause harmful interference to 
radio communications. 
Operation of this equipment in a residential area is likely to cause harmful interference in which 
case the user will be required to correct the interference a this own expense.

WARNING

-Changes or modifications not expressly approved by the manufacturer could void the 

user's authority to operate the equipment.

CAUTION :

 To prevent electric shock and risk of fire hazards:

              Do NOT use power sources other than that specified.
              Do NOT expose this appliance to rain or moisture.

* This installation should be made by a qualified service person and should conform to all local codes.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION :

TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

Summary of Contents for PS-100N

Page 1: ...TZ DOME CAMERA PS 100N PS 100P Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use W 388058120 PRINTED IN KOREA Distribute...

Page 2: ...en tested and found to comply with limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when...

Page 3: ...consisting of presets with individual dwell time Pattern Up to 4 programmable Patterns memorized the PTZ movement Area Up to 4 programmable Area display set Privacy zone masking Up to 4 programmable...

Page 4: ...s 1 loose proof screw In ceiling Mount To install and use the PS 100 the followings should be needed NOT included in box 1 Power adaptor Over 1A The power adaptor should have capacity over 1 Ampere Lo...

Page 5: ...ded in the camera box The Video and RS 485 control cables Power adaptor over 1A and installation tools are necessary to complete the installation For cable connection make a hole Hole size 70mm in the...

Page 6: ...85 control cables Power adaptor over 1A and installation tools are necessary to complete the installation For cable connection make a hole Hole size 110mm in the ceiling where you want to install the...

Page 7: ...en Display Menu INITIALIZE When you turn on the power the INITIALIZE screen on the monitor will appear During Initialization you can check the PTZ information If the information is different with your...

Page 8: ...LABEL STORE TELE MOVE JOY DEL WIDE BACK NEAR SAVE CLR BACK EXIT NEAR RIGHT SCAN NO SCAN MENU SCAN LABEL EDIT 01 S01 02 03 04 SEL NEAR MOVE JOYSTICK SCAN SELECT POSITION 359 9 45 0 EXIT FOCUS NEAR SCA...

Page 9: ...BEL EDIT 01 In the Privacy Position setup the masking size can be variable with the iris OPEN CLOSE key OPEN make the mask larger CLOSE make the mask smaller TITLE You can set the camera title and it...

Page 10: ...crease or decrease the Red or Blue values to shift the color of the object Red Red Gain can be changed Blue Blue Gain can be changed You can set the camera exposure a Brightness The brightness of the...

Page 11: ...mode to distinguish dark images clearly IRIS SET You can set the Iris mode Auto The brightness of the image signal can be adjusted automatically depending on the amount of light Manual The brightness...

Page 12: ...tation Speed Flip Lens Initialization Focus Control Iris Control Protocols Communication Power Consumption Operating Temperature Operating Humidity Certification Dimensions Weight QUICK COMMAND FUNCTI...

Reviews: