2.9.4
If the fireplace opening is greater than the acceptable dimensions given in this
guide, do not use the back of a fire surround or marble to reduce the opening. This
may cause cracking of the surround back or marble
.
2.10
The following flues are suitable:
•
225mm x 225mm conventional brick flue.
If a flue liner is used, it must be a minimum of 125mm diameter. The liner must be sealed
to the surrounding area above the fireplace opening and to the top of the chimney. An
approved terminal must be fitted.
•
A properly constructed precast flue conforming to B.S 1289.
•
A flue pipe with a minimum diameter of 127mm. See B.S 6461 Part 1 for suitable
materials. Metal flue pipes must comply with B.S 715.
2.10.1
The minimum effective height of the flue must be 3m.
2.10.2
The flue must be clear of any obstruction and its base must be clear of debris.
2.10.3
The flue must be completely sealed so that combustion products do not come
into contact with combustible materials outside the chimney.
2.10.4
The flue must serve only one fireplace.
2.11
If the fireplace opening is an underfloor draught type, it must be sealed to stop any
draughts.
2.12
An extractor fan may only be used in the same room as this appliance, or in any
area from which ventilation for the appliance is taken, if it does not affect the safe
performance of the appliance. Note the spillage test requirements detailed further on in
this manual. If the fan is likely to affect the appliance, the appliance must not be installed
unless the fan is permanently disconnected.
2.13
A fireguard complying with BS6539 or BS6778 should be fitted for the protection
of young children, the elderly, or the infirm.
2.14
The appliance is fitted with an A.S.D (Atmosphere sensing device). If the
appliance closes down after a period of operation for no apparent reason, the consumer
should be informed to stop using the appliance until the installation and appliance have
been thoroughly checked. The A.S.D will shut the appliance down if an unacceptable
amount of harmful products of combustion accumulate. Under no circumstances should
the A.S.D be altered or bypassed in any way. Only a genuine manufacturers replacement
part should be fitted. The individual A.S.D components are not replaceable.
2.15
This appliance may be installed with a surround with a minimum approved
temperature rating of 150 degrees. The fire surround must be sealed to the wall.