24
14.3
TO REMOVE THE FIRE FRONT
14.3.1
Remove the bottom front cover casting.
14.3.2
Lift the fire front casting up and forward to release the locating screw heads
at the back of the casting from the keyholes in the surround sides (See fig. 37). Lift
the casting clear.
14.3.3
Detach the control linking bar from the control pivot bracket by removing
the knurled screw (See fig. 28).
14.3.4
Remove the two screws securing the bottom of the front surround to the
sides of the convection box (See fig. 27).
14.3.5 Make sure that the control linking bar has been detached (see 14.3.3).
Carefully lift the surround unit upwards to clear the upper retaining brackets on the
convection box (See fig. 26). Pull the surround clear and place carefully aside.
14.3.6
Refit in the reverse order. Make sure that the surround is properly located
over the upper retaining brackets. See section 10 of this manual for detailed
fitting instructions.
14.4
TO REPLACE THE CONTROL SLIDE BUTTON
14.4.1
Remove the front unit - See section 14.3.
14.4.2
Detach the rear shield plate by removing two screws from the rear
right side of the front surround (See fig. 41).
14.4.3
Remove the two screws securing the slide button to the back of the
slide mechanism bar. Raise the button to clear the bar and pull through the
slot in the surround side (See fig. 41).
14.4.4
Refit in the reverse order.
14.5
TO REMOVE THE CONTROL SLIDE UNIT
14.5.1
Remove the surround unit and slide button - see section 14.4
14.5.2
Remove two screws securing the plastic slide mechanism box to the rear side of
the front casting. Lift the slide unit clear.
14.5.3
Refit in the reverse order.
14.6
TO REMOVE THE BURNER UNIT (See figure 42)
14.6.1
Remove the front surround unit- See section 14.3.
14.6.2
Remove the loose coals, the front coal and the base coal.
14.6.3
Remove the ceramic side and rear walls.
14.6.4
Support the inlet isolating elbow to avoid straining the pipework and disconnect
the appliance from the elbow.
14.6.5
Detach the burner unit from the convection box by removing 2 screws.
14.6.6
Replace in the reverse order.
14.7
TO REMOVE THE ELECTRONIC IGNITION GENERATOR
14.7.1
Remove the bottom front and fire front castings and front surround - see section
14.3.
14.7.2
Remove the battery.
14.7.3
Remove the burner unit – see section 14.6.
14.7.4
Remove the two leads to the switch and remove the spark lead, marking them if
Necessary to ensure that they are replaced on to the correct terminals.
14.7.5
Remove the two fixing screws that attach the generator unit to the bracket. The
igniter generator can now be exchanged.
14.7.6
Refit in the reverse order.
Fig. 42 Burner removal points
Fig. 41 Control Slide Unit
Summary of Contents for Marseille BR622