4

In order to change from one setting to another depress the control knob slightly and
turn the knob to the required position.  Alternatively, if a setting between LOW and
HIGH is required, then the control knob may be turned to this position.

Note: We recommend you use the appliance at a low setting for the first few hours of
use to reduce the thermal cracking of the surface of the burner.
Surface cracking of the burner is normal and is no cause for concern. Whist binding
materials are being burnt out of the burner there may be a slight odour.

To Turn the Fire back to Pilot Setting

Depress control knob and turn clockwise until pilot setting is reached.
To Turn the Fire OFF Ensure control knob is in pilot position, depress control knob
and turn clockwise to the OFF position.

For fires fitted with Aeration control

For appliances fitted with variable aeration control, the lighting and adjustment
procedures are as normal. To operate the aeration control system, the following
procedure should be followed:

 

Allow the appliance to warm up, (for at least fifteen minutes) in the fully aerated
position, with the control lever pushed in to the locked position – see figure 3.

 

Switch to the minimum aerated position by slightly lifting the control lever. A
spring mechanism will close the aeration shutter.

 

To return to the fully aerated position push the control lever in and slightly
downwards until it rests in its locked position.

Please note : It is advisable to run the fire in its fully aerated mode (control knob
pushed in) at the beginning of each operation and if running at the minimum rate
setting, or to burn off any carbon deposits which may have built up after prolonged
use of the minimum aerated setting.

Figure 3

Summary of Contents for airflame excel mk.3 ac 18xl

Page 1: ...L MK 3 AF 18XL 9500360 AC 18XL 9500361 USER MANUAL Patent applied for 9860370 03 Please leave these Instructions with the user This appliance is for use in the United Kingdom GB and the Republic of Ir...

Page 2: ...If the appliance shuts down after a period of operation for no apparent reason then stop using the appliance until the installation and the appliance have been thoroughly checked by a competent perso...

Page 3: ...o activate the piezo ignition Two clicks will be observed and the pilot should ignite Hold the knob in this position keeping it depressed for ten seconds to allow the flame supervision device to estab...

Page 4: ...e to the OFF position For fires fitted with Aeration control For appliances fitted with variable aeration control the lighting and adjustment procedures are as normal To operate the aeration control s...

Page 5: ...nance instructions However if your fire is used frequently the coals may need cleaning The coals should be removed and any sooting carefully removed from the surface with a soft brush The burner surfa...

Page 6: ...e effect it is important that the coals are evenly spaced and sit 10 15mm from each other Next take five random shaped coals and position as shown in figure 7 This second row of coals should rest on t...

Page 7: ...correct quantity and follow the instructions carefully Description Part Number Front coal 9770100 Coal matrix 9770099 Pack of dress coals 9780050 GUARANTEE Every Wonderfire product is warranted for a...

Page 8: ...vice department If you require your fire to be serviced or in the unlikely event that it should require repair due to a manufacturing defect then call Wonderfire service department on 0121 386 203 quo...