![WoMaster LoRa LC144 User Manual Download Page 33](http://html1.mh-extra.com/html/womaster/lora-lc144/lora-lc144_user-manual_994005033.webp)
Address
Name
Type
Description
40001
Baud Rate
R/W
0
:
9600
1
:
4800
2
:
2400
3
:
1200
Hex Code, 1 Byte
40002
Data Length
R/W
8
:
8 Data Bits
HEX Code, 1Byte
40003
Stop Bit
R/W
1
:
1 Stop bit
2
:
2 Stop bit
HEX Code, 1 Byte
40004
Parity Check
R/W
0
:
None Parity Check
1
:
Even
2
:
Odd
Hex Code, 1 Byte
40005
MODBUS Device ID
R/W
1~250, 1 Byte
HEX Code
40022
Lora_freq_band
R/W
Unit
:
0.1MHz
40023
Lora_TX Power
R/W
2byte
14~22 Unit
:
dBm
HEX Code, Big Endian
40024
Lora_Spreading Factor
R/W
0:SF5 1:SF6
2:SF7 3:SF8
4:SF9 5:SF10
6:SF11 7:SF12
HEX Code
40025
Lora_Bandwidth
R/W
0:125Khz
1:250Khz
2:500Khz
HEX Code
40026
Lora_Code Rate
R/W
1:4/5
2:4/6
3:4/7
4:4/8
HEX Code
40101
Source ID (Group Net
Owner – LM100)
R/W
Range
:
1~250
HEX code
40102
Bitmap
R/W
1.RTU device connected
with LC device