![WolfVision VZ-9plus3 Instructions Manual Download Page 20](http://html1.mh-extra.com/html/wolfvision/vz-9plus3/vz-9plus3_instructions-manual_993803020.webp)
Anti-theft device 2: table lock bolt
The Visualizer can be fixed with a
, so that it
can not be stolen
.
Follow the instructions from the cable lock manual.
®
security cable T-bar lock (Kensington Lock)
Anti-theft device 1: T-bar lock
slot for lock
The Visualizer can also be fixed onto a table with the
supplied table lock bolt in order to minimize the risk of
theft.
Please note that the usable depth of thread is 8mm, do not
screw in more than this.
Supplied accessories:
1x Socket head cap wrench 5mm
(101684)
1x Allen screw driver 2,5mm
(101685)
1x Screw M8x35
(101686)
1x Screw M8x50
(101687)
2x Washer 8.4/16x1.6
(100527)
1x Assembly instructions VZ-9plus³
(
)
103259
Lock Turntable
Remove the screw from the hole position 2 and insert it
into the specific hole position 1 (the turntable might have
to be turned until the thread is visible).
Use supplied Allen screw driver (2,5mm).
table
(sectional view)
washer 8.4/16x1.6
screw M8x35 or
screw M8x50
Turntable
19
If the unit gets too hot (improper ventilation, or air extraction or too high ambient temperature) a built in
thermal sensor will switch off the light of the Visualizer.
Verify that proper ventilation and air extraction is available and allow the unit to cool!
The rotation speed of the blower is temperature controlled.
Thermostat
attachment
area
2
1
M8
167
[6 5/8"]
185
[7 1/4"]