WM9090
Production Data
w
PD, November 2010, Rev 4.1
46
Secondly, initiate the sequence by performing the following set of register writes.
REGISTER
ADDRESS
DATA DESCRIPTION
R1 (01h)
Power Management (1)
0x000B OSC_ENA=1,
VMID_RES=01,
BIAS_ENA=1
R2 (02h)
Power Management (2)
0x60C0 Enable
input
PGAs
R22 (16h)
IN1 Line Control
0x0000
IN1+/- to s/e mode and disable input
clamp
R24 (18h)
IN1 Line Input A Volume
0x0100
IN1A Volume=-6dB and update
R25 (19h)
IN1 Line Input B Volume
0x0100
IN1B Volume=-6dB and update
R70 (46h)
Write Sequencer 0
0x0100
Write Sequencer enable
R71 (47h)
Write Sequencer 0
0x0100 WSEQ_START=1