Introduction 

The PGT

®

130.DT is a compact testing system for checking Personnel grounding with ESD shoes, 

wrist straps systems and smocks according to IEC 61340-5-1 and ANSI ESD S20.20. 
 
The user identification is possible via integrated RFID reader or via any external HID-compatible 
USB input device e.g. barcode scanner, keyboard or magnetic stripe reader. 
 
Multiple devices can be networked together and managed by the DataTermD software. User data 
and measurement data can be managed centrally. 
 

General notice: 

Persons with pacemaker or pregnant women should consult a doctor before using the device. 

 

The PGT

®

130.DT must be operated with the originally supplied power supply. 

 
The maximum USB cable length is 2 m 
 

Notice for measurement: 

The sensor plate must be pressed with several finger tips at once. 
After a short time period  the measurement values are displayed. 

Keep the sensor plate pressed during the complete measurement.

 

 

 

Notice for RFID:

 

The integrated universal RFID reader can read the frequencies 125 kHz / 134,2 kHz and 
13,56 MHz. This includes common transponder types like EM4x, HITAG, ISO14443A, 
ISO14443B, ISO15693. 
 

By default the unique serial number of the presented card is read in hexadecimal notation. 
 
Please contact us for individual configuration if your company cards are not detected or if 
you need different data of the card for personnel identification.   
 
If you‘re using dual cards (ID-cards with two different transponders) your card can be 
detected with two different ID‘s. Contact us to adjust the reader to your requirements. 
 

Important Notice 

Please read the following instructions carefully. 
1. PGT

®

130.DT cleaning 

§

  Switch off the device by disconnecting the power supply 

§

  Spray a non-solvent based cleaner onto a soft fabric and wipe the surface carefully 

2. Don‘t remove the cover, don‘t try to repair the device yourself 
3. Observe the operating conditions 
4. The USB cable length must not exceed 2 meter 
5. Use only the power supply, which was included in the scope of delivery 

 

 

Summary of Contents for PGT130.DT

Page 1: ...User s Manual PGT 130 DT Part No 7100 PGT130 DT Page 1 21 V12 2020 User s Manual Personnel Grounding Tester PGT 130 DT V1 2...

Page 2: ...ents 2 Introduction 3 Important Notice 3 Scope of Delivery 4 Installation 4 Initial Operation Local 6 Initial Operation via Network 7 Configuration 8 Operation 13 Device specification 15 Limits and mo...

Page 3: ...Keep the sensor plate pressed during the complete measurement Notice for RFID The integrated universal RFID reader can read the frequencies 125 kHz 134 2 kHz and 13 56 MHz This includes common transp...

Page 4: ...r supply EU US Footwear electrode User s manual Calibration certificate German English Installation Device overview Rear Connections Colour Display Internal RFID Reader Sensor plate Wrist strap power...

Page 5: ...user was identified Contact between pin 3 and 4 Contact less solid state relay to switch 24V DC 16V AC ohmic load up to 2A Output contact Pin 3 and 4 Footwear electrode Cable outlet is configurable t...

Page 6: ...livery Rebooting is required to activate new connected USB devices Initial Operation Local If you operate the device in stand alone you can configure it in front via display The symbols for wrist and...

Page 7: ...t settings are in bold Initial Operation via Network The PGT 130 DT is ready within 50 seconds after plugging in the power supply If the Ethernet cable is connected the device tries to configure its n...

Page 8: ...m settings Company name or independent text This will be printed on the first line of each label The user ID can be printed instead if user identification is enabled and this field is blank WEB interf...

Page 9: ...1s 2s 3s Internal RFID reader ON OFF OFF external or no input device Enable Disable configuration buttons ON OFF Tempering protection Manual IP Address Configuration Log into the configuration page w...

Page 10: ...d user data as TEXT CSV file Optional beacon Signal light timing Signal light buzzer settings Sysinfo Display of software versions System time Device s IP and MAC address Last measurement poll time La...

Page 11: ...time and test result Measurement data view is updated every 20 seconds The current temperature and the relative humidity is recorded if the T H Sensor is connected For identified users the user ID sho...

Page 12: ...wrist 4 Single shoe 6 Wrist and single shoe 8 Wrist with glove print Label print Integer 0 off 1 on View with MS EXCEL Data stored as CSV or TXT file Additional Option profile If there is a specific n...

Page 13: ...required measurement according to the specified user profile Left wrist strap right shoes 3 Touch only one sensor plate for measurement Test without user identification If user identification is disa...

Page 14: ...nsor with the glove After a short measurement time the color test result green pass red fail and the measurement values are displayed Hands free test shoe to shoe This operating mode is globally selec...

Page 15: ...nditions 10 60 C bis 75 r F Display Result display Colour display Measure ranges Wrist 100 k 200 M 5 200 M 1 G 10 Footwear 100 k 200 M 5 Interface Wrist Snap 10 mm 2 x socket 4 mm Footwear 2 x socket...

Page 16: ...ndoor operation Table top Wall mounting with optional wall mounting bracket compliant Calibration To test the instrument accuracy you can use the optional available Calibration Unit for PGT130 DT Deta...

Page 17: ...ied extension cable to the device Type DT USB TF Part No 7100 PGT130 DT TF Label Printer Label printing for passed tests with test results and measurement values The device is compatible with Seiko La...

Page 18: ...listed devices a passive HUB without additional power supply is sufficient Type USB HUB4 Part No 7100 PGT120 TEST 16 Waste disposal According to WEEE Directive 2012 19 EU the device is marked with th...

Page 19: ...st Strap kOhm Integer 7 erg OK or ErrorCode Number or String see below 8 msg Terminals Message text String see below 9 id User ID RFID Reader data Filter ASCII 32 127 max 30 digits 10 tmp Temperature...

Page 20: ...e of Measurement 2011 01 19 2 time Time of Measurement 16 53 3 rsg Result Shoes in Series kOhm Integer 4 rsl Result Shoe left kOhm Integer 5 rsr Result Shoe right kOhm Integer 6 rhg Result Wrist Strap...

Page 21: ...Ohm Integer 4 rsl Result Shoe left kOhm Integer 5 rsr Result Shoe right kOhm Integer 6 rhg Result Wrist Strap kOhm Integer 7 erg OK or ErrorCode Number or String see below 8 msg Terminals Message text...

Reviews: