background image

5

I N S TA L L AT I O N

I N S T R U C T I O N S

M O D E L W W D 3 0

with Stainless Steel Drawer Front

Overall Width

29

7

/

8

" (759)

Overall Height

10

1

/

4

" (260)

Overall Depth

27

1

/

8

" (689)

Depth Behind Frame*

23

1

/

2

" (597)

Minimum Cabinet Width

30" (762)

Minimum Cabinet Depth

24" (610)

Minimum Base Support

200 lbs (91 kg)

Opening Width

28

5

/

8

" (727)

Opening Height

9

1

/

8

" (232)

Opening Depth

23

7

/

8

" (606)

*Allow 

3

/

8

" (10) additional depth for cord thickness.

S TA I N L E S S S T E E L

D R A W E R F R O N T

I N S T A L L A T I O N S P E C I F I C A T I O N S

The following illustrations provide the overall
dimensions and installation specifications for
the Wolf warming drawer with a stainless steel
drawer front.

Wolf recommends using a 33" (838) wide
cabinet for the warming drawer with stainless
steel drawer front. A minimum 30" (762) wide
by 24" (610) deep cabinet is required with a
minimum base support of 200 lbs (91 kg).

Refer to pages 14–15 for stainless steel drawer
front installation instructions. These instruc-
tions are also included with the stainless steel
drawer front kit.

U N D E R C O U N T E R   I N S T A L L A T I O N  

For undercounter installations, 23

1

/

2

" (597)

from the bottom of the warming drawer
opening to the floor is recommended. It must
be installed a minimum of 5" (127) above the
floor or 1" (25) above the toe kick.

The Wolf warming drawer with stainless steel
drawer front may be installed below an electric
or gas cooktop, provided the warming drawer
is fully enclosed, top and bottom. Allow
enough room for gas and electrical connec-
tions for the cooktop. Refer to installation
instructions for the cooktop for additional
specifications. Dimensions will vary according
to the specific installation.

28

5

/

8

"

(727)

OPENING WIDTH

E

5"

(127)

4"

(102)

33" 

(838)

RECOMMENDED CABINET WIDTH

30"

min (762)

36" 

(914)

STANDARD

FLOOR TO
COUNTER

HEIGHT

5"

min (127)

BOTTOM 

OF OPENING

TO FLOOR

24"

min (610)

CABINET DEPTH

9

1

/

8

"

(232)

OPENING

HEIGHT

23

7

/

8

"

min (606)

OPENING DEPTH

2"

(51) x 

2"

(51)

ANTI-TIP BLOCK

DIMENSION

WILL VARY*

ALLOW FOR

5

/

8

"

(16)

OVERLAP OF

DRAWER FACE

ON ALL SIDES

*Allow enough room for placement of anti-tip block and drawer face overlap.

23

1

/

2

"

(597)

BEHIND FRAME

29

7

/

8

"

(759)

OVERALL WIDTH

9"

(229)

27

1

/

8

"

(689)

OVERALL DEPTH

10

1

/

4

"

(260)

Overall Dimensions – Stainless Steel Drawer Front

Undercounter Installation – Stainless Steel Drawer Front

Summary of Contents for WWD30

Page 1: ...INSTALLATION INSTRUCTIONS W A R M I N G D R A W E R ...

Page 2: ...would like to identify is IMPORTANT NOTE This highlights informa tion that is especially relevant to a problem free installation signals a situation where minor injury or product damage may occur if you do not follow instructions states a hazard that may cause serious injury or death if precautions are not followed WOLF is a registered trademark of Wolf Appliance Company LLC C O N TA C T I N F O R...

Page 3: ...structions prior to installation Save these instructions for the local inspector s refer ence then leave them with the homeowner Homeowner Please read and keep these instructions for future reference and be sure to read the entire Use Care Information prior to use Any questions or problems about the installation should be directed to your Wolf dealer or Wolf Appliance Company LLC at 800 332 9513 Y...

Page 4: ...integrated drawer front application A C C E S S O R I E S Optional acces sories are available through your Wolf dealer To obtain local dealer information visit the Locator section of our website wolfappliance com BEFORE YO U S TA RT Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Wolf warranty Refer to the Warming Dra...

Page 5: ... E R C O U N T E R I N S TA L L AT I O N For undercounter installations 231 2 597 from the bottom of the warming drawer opening to the floor is recommended It must be installed a minimum of 5 127 above the floor or 1 25 above the toe kick The Wolf warming drawer with stainless steel drawer front may be installed below an electric or gas cooktop provided the warming drawer is fully enclosed top and...

Page 6: ... oven for additional specifications Dimensions will vary according to the specific installation The Wolf warming drawer is designed and agency approved for installation with Wolf built in ovens The warming drawer platform must be able to support 200 lbs 91 kg It must be a minimum of 1 25 above the toe kick to allow for the overlap of the warming drawer trim Installation with Built In Oven Stainles...

Page 7: ...nation with a 30 762 single oven and microwave oven with 30 762 trim provided the warming drawer is fully enclosed top and bottom Refer to the illustration below Also refer to installation instructions provided with the built in oven and microwave for additional specifications Dimensions will vary according to the specific installation The warming drawer platform must be able to support 200 lbs 91...

Page 8: ...lacement of anti tip block and drawer face overlap Overlap of decorative drawer face will vary depending on the size of the custom panel 101 4 260 OPENING HEIGHT 97 8 251 2 51 x 2 51 ANTI TIP BLOCK 293 8 746 OVERALL WIDTH 231 2 597 BEHIND FRAME 9 229 101 8 257 Overall Dimensions Integrated Drawer Front Integrated Drawer Front Overlay Application INTEGRATED D R AW E R F RO N T I N S TA L L AT I O N...

Page 9: ...ORTANT NOTE The inset application requires the warming drawer to be recessed into the cabinet A minimum 25 635 deep cabinet is needed if you want the front panel to be flush with surrounding cabinetry If you are installing the warming drawer with integrated drawer front in an inset application a minimum 33 838 wide and 25 635 deep cabinet is required for this installation A minimum base support of...

Page 10: ...d bottom Refer to the illustration below Also refer to installation instructions provided with the built in oven for additional specifications Dimensions will vary according to the specific installation The Wolf warming drawer is designed and agency approved for installation with Wolf built in ovens The warming drawer platform must be able to support 200 lbs 91 kg It must be a minimum of 1 25 abov...

Page 11: ...ven and Microwave Integrated Drawer Front Refer to installation instructions provided with the built in oven and microwave for additional specifications Dimensions will vary according to the specific installation The Wolf warming drawer with integrated drawer front may be installed next to or above another Wolf warming drawer provided each unit is fully enclosed top and bottom INTEGRATED D R AW E ...

Page 12: ... it is placed behind the unit make sure the outlet is flush with the back wall For location of the electrical outlet refer to the installation illustration for your specific installation on pages 5 11 The electrical outlet can be located in an adjacent cabinet within reach of the power cord If the outlet is located in an adjacent cabinet you will need to drill a 2 51 diameter hole in the cabinet w...

Page 13: ...sh with the bottom edge of the opening They must be able to support 200 lbs 91 kg If an integrated drawer front is used it must be supported by a 5 8 16 solid platform The platform will need to be recessed and allow for overlap of the warming drawer collar Refer to page 16 for additional details The platform must be level rigidly mounted and must be able to support 200 lbs 91 kg IMPORTANT NOTE Mak...

Page 14: ... 16 8 long screws provided in the kit to secure these two pieces together Repeat this process to attach the right side and bottom trim 14 W O L F WARMING DRAWER STAINLESS STEEL F RO N T PA N E L I N S TA L L A N T I T I P B L O C K I N G Install a 2 51 x 2 51 or 2 51 x 4 102 anti tip block against the rear cabinet wall When the warming drawer is installed below a built in oven you may use a 7 8 22...

Page 15: ...er front assembly and tighten screws Refer to the illustration below Turn power off to the electrical outlet I N S TA L L WA R M I N G D R AW E R Slide the left corner of the warming drawer into the opening If the electrical outlet is installed inside the opening plug the power cord into the outlet The excess cord should be coiled behind or beside the unit If the outlet is located in an adjacent c...

Page 16: ...at it can support a minimum of 200 lbs 91 kg Refer to the illustrations below IMPORTANT NOTE In an overlay application be sure to recess the cleats no more than 3 16 5 Recessing deeper than this may cause the drawer to not close properly W O L F WARMING DRAWER IMPORTANT NOTE Be sure to finish the inside lip of the opening and the front face of the shelf and cleats Some of these areas will be visib...

Page 17: ...o the opening If the electrical outlet is installed inside the opening plug the power cord into the outlet The excess cord should be coiled behind or beside the unit If the outlet is located in an adjacent cabinet thread the power cord through the hole in the cabinet wall Push the unit back into the opening until the warming drawer collar meets up with the recessed cleats and platform Make sure th...

Page 18: ...e edge of the oblong holes to the the corresponding oblong hole below it The markings on the back of the decorative panel should look like the bottom panel illus tration below For every round marking on the decorative panel 12 locations drill a 1 2 hole 1 4 6 deep in the back of the panel Route out the rectangular areas 8 locations marked on the back of the decorative panel 1 4 6 deep Attach the h...

Page 19: ...alling a Wolf authorized service center For the name and number of the Wolf authorized service center nearest you check the Locator section of our website wolfappliance com or call Wolf Customer Service at 800 332 9513 When calling for service you will need the model and serial numbers of the warming drawer Both numbers are listed on the product rating plate located on the left front floor area of...

Page 20: ...8 0 8 2 1 2 4 2 0 0 6 WOLF APPLIANCE COMPANY LLC P O BOX 44848 MADISON WI 53744 800 332 9513 WOLFAPPLIANCE COM ...

Reviews: