background image

18

W O L F  

WA R M I N G   D R AW E R

I N T E G R AT E D  

F R O N T   P A N E L

I N S T A L L   F R O N T   P A N E L  T O   D R A W E R

Remove the front panel that came attached to
the warming drawer. Save the six screws used
to attach the panel.

Using the six screws, install the metal panel
from the integrated drawer front kit onto the
warming drawer front. Make sure the brushed
side of the metal panel is facing the warming
drawer interior.

Temporarily place the decorative front panel
against the metal panel and make sure it is in
its correct final position.

Open the drawer. Trace the holes in the metal
panel onto the back of the decorative panel.
Remove the decorative panel. The markings on
the back of the decorative panel should look
like the top panel illustration below.

Draw a line from the edge of the oblong holes
to the the corresponding oblong hole below it.
The markings on the back of the decorative
panel should look like the bottom panel illus-
tration below.

For every round marking on the decorative
panel (12 locations), drill a 

1

/

2

" hole, 

1

/

4

" (6)

deep in the back of the panel.

Route out the rectangular areas (8 locations)
marked on the back of the decorative panel

1

/

4

" (6) deep.

Attach the handle hardware to the front of the
decorative panel. The integrated drawer front
kit does not include a handle. This allows the
homeowner to match handle hardware with
the surrounding cabinetry.

Install the six rubber bumpers, provided with
the drawer front kit, onto the metal panel.
Attach the decorative panel to the warming
drawer using the six 

1

/

2

" screws provided with

the kit. Refer to the illustration below for
location of bumpers and screws.

Rubber Bumper

Decorative

Panel

Screw

Metal
Panel

Location of bumpers and mounting
screws

Back view of decorative panel

Summary of Contents for WWD30

Page 1: ...INSTALLATION INSTRUCTIONS W A R M I N G D R A W E R ...

Page 2: ...would like to identify is IMPORTANT NOTE This highlights informa tion that is especially relevant to a problem free installation signals a situation where minor injury or product damage may occur if you do not follow instructions states a hazard that may cause serious injury or death if precautions are not followed WOLF is a registered trademark of Wolf Appliance Company LLC C O N TA C T I N F O R...

Page 3: ...structions prior to installation Save these instructions for the local inspector s refer ence then leave them with the homeowner Homeowner Please read and keep these instructions for future reference and be sure to read the entire Use Care Information prior to use Any questions or problems about the installation should be directed to your Wolf dealer or Wolf Appliance Company LLC at 800 332 9513 Y...

Page 4: ...integrated drawer front application A C C E S S O R I E S Optional acces sories are available through your Wolf dealer To obtain local dealer information visit the Locator section of our website wolfappliance com BEFORE YO U S TA RT Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Wolf warranty Refer to the Warming Dra...

Page 5: ... E R C O U N T E R I N S TA L L AT I O N For undercounter installations 231 2 597 from the bottom of the warming drawer opening to the floor is recommended It must be installed a minimum of 5 127 above the floor or 1 25 above the toe kick The Wolf warming drawer with stainless steel drawer front may be installed below an electric or gas cooktop provided the warming drawer is fully enclosed top and...

Page 6: ... oven for additional specifications Dimensions will vary according to the specific installation The Wolf warming drawer is designed and agency approved for installation with Wolf built in ovens The warming drawer platform must be able to support 200 lbs 91 kg It must be a minimum of 1 25 above the toe kick to allow for the overlap of the warming drawer trim Installation with Built In Oven Stainles...

Page 7: ...nation with a 30 762 single oven and microwave oven with 30 762 trim provided the warming drawer is fully enclosed top and bottom Refer to the illustration below Also refer to installation instructions provided with the built in oven and microwave for additional specifications Dimensions will vary according to the specific installation The warming drawer platform must be able to support 200 lbs 91...

Page 8: ...lacement of anti tip block and drawer face overlap Overlap of decorative drawer face will vary depending on the size of the custom panel 101 4 260 OPENING HEIGHT 97 8 251 2 51 x 2 51 ANTI TIP BLOCK 293 8 746 OVERALL WIDTH 231 2 597 BEHIND FRAME 9 229 101 8 257 Overall Dimensions Integrated Drawer Front Integrated Drawer Front Overlay Application INTEGRATED D R AW E R F RO N T I N S TA L L AT I O N...

Page 9: ...ORTANT NOTE The inset application requires the warming drawer to be recessed into the cabinet A minimum 25 635 deep cabinet is needed if you want the front panel to be flush with surrounding cabinetry If you are installing the warming drawer with integrated drawer front in an inset application a minimum 33 838 wide and 25 635 deep cabinet is required for this installation A minimum base support of...

Page 10: ...d bottom Refer to the illustration below Also refer to installation instructions provided with the built in oven for additional specifications Dimensions will vary according to the specific installation The Wolf warming drawer is designed and agency approved for installation with Wolf built in ovens The warming drawer platform must be able to support 200 lbs 91 kg It must be a minimum of 1 25 abov...

Page 11: ...ven and Microwave Integrated Drawer Front Refer to installation instructions provided with the built in oven and microwave for additional specifications Dimensions will vary according to the specific installation The Wolf warming drawer with integrated drawer front may be installed next to or above another Wolf warming drawer provided each unit is fully enclosed top and bottom INTEGRATED D R AW E ...

Page 12: ... it is placed behind the unit make sure the outlet is flush with the back wall For location of the electrical outlet refer to the installation illustration for your specific installation on pages 5 11 The electrical outlet can be located in an adjacent cabinet within reach of the power cord If the outlet is located in an adjacent cabinet you will need to drill a 2 51 diameter hole in the cabinet w...

Page 13: ...sh with the bottom edge of the opening They must be able to support 200 lbs 91 kg If an integrated drawer front is used it must be supported by a 5 8 16 solid platform The platform will need to be recessed and allow for overlap of the warming drawer collar Refer to page 16 for additional details The platform must be level rigidly mounted and must be able to support 200 lbs 91 kg IMPORTANT NOTE Mak...

Page 14: ... 16 8 long screws provided in the kit to secure these two pieces together Repeat this process to attach the right side and bottom trim 14 W O L F WARMING DRAWER STAINLESS STEEL F RO N T PA N E L I N S TA L L A N T I T I P B L O C K I N G Install a 2 51 x 2 51 or 2 51 x 4 102 anti tip block against the rear cabinet wall When the warming drawer is installed below a built in oven you may use a 7 8 22...

Page 15: ...er front assembly and tighten screws Refer to the illustration below Turn power off to the electrical outlet I N S TA L L WA R M I N G D R AW E R Slide the left corner of the warming drawer into the opening If the electrical outlet is installed inside the opening plug the power cord into the outlet The excess cord should be coiled behind or beside the unit If the outlet is located in an adjacent c...

Page 16: ...at it can support a minimum of 200 lbs 91 kg Refer to the illustrations below IMPORTANT NOTE In an overlay application be sure to recess the cleats no more than 3 16 5 Recessing deeper than this may cause the drawer to not close properly W O L F WARMING DRAWER IMPORTANT NOTE Be sure to finish the inside lip of the opening and the front face of the shelf and cleats Some of these areas will be visib...

Page 17: ...o the opening If the electrical outlet is installed inside the opening plug the power cord into the outlet The excess cord should be coiled behind or beside the unit If the outlet is located in an adjacent cabinet thread the power cord through the hole in the cabinet wall Push the unit back into the opening until the warming drawer collar meets up with the recessed cleats and platform Make sure th...

Page 18: ...e edge of the oblong holes to the the corresponding oblong hole below it The markings on the back of the decorative panel should look like the bottom panel illus tration below For every round marking on the decorative panel 12 locations drill a 1 2 hole 1 4 6 deep in the back of the panel Route out the rectangular areas 8 locations marked on the back of the decorative panel 1 4 6 deep Attach the h...

Page 19: ...alling a Wolf authorized service center For the name and number of the Wolf authorized service center nearest you check the Locator section of our website wolfappliance com or call Wolf Customer Service at 800 332 9513 When calling for service you will need the model and serial numbers of the warming drawer Both numbers are listed on the product rating plate located on the left front floor area of...

Page 20: ...8 0 8 2 1 2 4 2 0 0 6 WOLF APPLIANCE COMPANY LLC P O BOX 44848 MADISON WI 53744 800 332 9513 WOLFAPPLIANCE COM ...

Reviews: