12
W O L F
P R O WA L L V E N T I L AT I O N
H O O D S
Rough-In Plate
Mounting Holes
Soffit
Hood installation
L OW- P R O F I L E
A N D
2 4 " ( 6 1 0 )
H O O D S
S T E P 5 : I N S T A L L T H E H O O D
IMPORTANT NOTE:
If a backsplash is to be
used, it should be installed before the wall
hood is mounted.
Align the hood assembly with the marked
location.
Install the #10 x 2" (59) screws (included
with the hood) through the mounting holes
on the rough-in plate. Verify that the screws
engage the wall studs or framing. If not,
wall anchors must be used.
Attach the transition to existing ductwork
with sheet metal screws and duct sealing
tape.
Due to the weight of the hood, be
sure to have adequate manpower for
installation.
C O M P L E T E T H E I N S T A L L A T I O N
To complete the installation for the low-profile
and 24" (610) deep wall hoods, follow Step 6:
Install Wiring and refer to information on
pages 17–19 for internal, in-line and remote
blowers.
Follow instructions to install the filters and
grease cups on page 21. If you will be attach-
ing the Wolf logo nameplate, follow the steps
on page 22.