![Wolf Vulcan SCB25 Installation & Operation Manual Download Page 9](http://html.mh-extra.com/html/wolf/vulcan-scb25/vulcan-scb25_installation-and-operation-manual_992313009.webp)
-
9
-
LIGHTING THE GAS PILOT
1.
Turn
main
gas
shut
‐
off
valve
and
the
individual
burner
gas
valves
OFF.
Wait
5
minutes.
2.
Remove
the
top
grates
and
radiants.
Turn
the
main
gas
shut
‐
off
valve
ON.
Light
pilots
using
a
lit
taper.
See
Fig.
6.
Adjust
the
pilot
valve
screw
until
the
pilot
flame
has
a
slight
yellow
tip.
3.
To
light
the
burners,
turn
the
individual
burner
valves
ON.
4.
If
the
burners
fail
to
light,
turn
all
valves
and
the
main
gas
shut
‐
off
to
the
OFF
position
and
contact
an
authorized
service
agency.
PILOT ADJUSTMENT
TO COMPLETELY SHUTDOWN THE BURNERS AND PILOT LIGHTS
For complete shutdown: Turn the main gas shut-off valve OFF. (Make sure all individual
burner valves are off before relighting.)
PREHEATING THE CHARBROILER
Allow the charbroiler to preheat for 30 minutes. Rub grates with cooking oil before using.
Fig. 7
FIG. 6
Pilot
Using a flathead screwdriver, turn the
slotted hex-head pilot adjustment
screw clockwise to decrease the
flame, and counter clockwise to
increase the flame. See Fig. 7.
Pilot Adjustment Screws
Summary of Contents for Vulcan SCB25
Page 14: ... 14 NOTES ...
Page 15: ... 14 REMARQUES ...