8
I N S T A L L T H E W I R I N G
This ventilation hood must be pro-
perly grounded, This unit should be
installed by a qualified electrician in
accordance with all applicable
national and local codes.
IMPORTANT NOTE:
Do not run or
remove blower electrical connections
through duct work.
1)
Run 120 VAC, 15 AMP minimum
circuit electric power cable from the
service panel to the junction box at
the center of hood. Supply 20”
minimum of Romex wire.
2)
Remove the knockout located on
the left side of the hood top plate.
See below illustrations for specific
location and dimensions of knockout.
3)
Feed the conduit through the hole
on top of the hood to junction box
located in center of hood shell.
4)
Remove the junction box cover
and connect black to power supply
black wire, white to power supply
white wire and green wire to green
or bare wire.
5)
Place all wiring connections inside
junction box and re-install cover.
Make sure that all wires are secure
and that no wires are pinched
between cover and box.
Island Hood Top Transition
WARNING
Before servicing or cleaning
unit, switch power off at service
panel and lock the service dis-
connecting means to prevent
power from being switched on
accidentally. When the service
disconnecting means cannot be
locked, securely fasten a promi-
nent warning device, such as a
tag, to the service panel.
P
R O
S
E R I E S
I
S L A N D
H
O O D
I
N S T A L L A T I O N
I N T E R N A L B L O W E R
IMPORTANT NOTE:
Before turning
the power on, make sure the blower
is in the "OFF" position. Use wire con-
nectors or wire nuts approved by UL
or C/UL. Refer to installation instruc-
tions provided with each blower to
verify island or roof cut-outs.
IBLOWER-120REM (804703)
Installation
1)
Remove hood filter and centerfil-
ter bank from hood. See page 6 for
instructions
2)
Lift ventilator into position inside
the hood.
3)
Engage two (2) Tabs on Ventilator
into two (2) Slots in Top of Hood.
Secure ventilator to Threaded Studs
with two (2) Hex Nuts (provided.)
4)
Plug ventilator's power cords into
receptacles inside the hood. Be sure
to secure power cords with clips on
hood interior so as not to damage
during operation of blower.
5)
Replace filters and center filter
bank once blower installation is com-
plete. See page 6 for direction.
WARNING
HEX NUTS
THREADED
STUDS
TOP OF
HOOD
POWER
CORDS
RECEPTACLES
TAB
SLOT
VENTILATOR
Internal Ventilator Blower
0.875"
(22 mm)
(Electrical)DIA. HOLE
RECTANGULAR HOLE
5.875" x 8"
(149 mm x 203 mm)
A
B
Wiring Diagram:
Refer to the wiring diagram pack-
aged with the hood for more
information.
(A) Dimension in from
left side of hood
(B) dimension back
from front of hood to
center of knock-out
Hood Size
36" (914mm)
1" (25mm)
1" (25mm)
42" (1067mm)
2" (51mm)
1 1/2" (38mm)
54" (1372mm)
8" (203mm)
1 1/2" (38mm)
Island Hood Electrical Knockout Location
Island Hood Electrical Knockout Dimensions