Wolf I363418 Installation Instructions Manual Download Page 6

6

H O O D   P R E P A R A T I O N

IMPORTANT NOTE:

If installing a duct cover, the duct
cover must be installed prior to hood
installation. See page #10  for duct
cover installation instructions or fol-
low those packed with duct cover.

1) 

Remove hood filters from hood

shell.

2) 

Remove center filter bank by

removing the 2 screws from each
side. DO NOT DISCARD THESE
PARTS, as they will be reinstalled after
hood installation is complete.

3) 

The hood assembly is shipped with

the transition attached. The transition
is shipped upside down in the top of
the hood assembly and must be
removed and reinstalled.

4) 

Detach the transition from the

hood assembly by removing the (4)
screws on the top of the hood assem-
bly. DO NOT DISCARD SCREWS.
Shipping screws are needed for the
reinstallation of the transition to
hood.

5) 

Invert transition so that the 10”

round points away from top of hood.
Use screws removed from step 4. 

6) 

If installing a remote blower, drill

7/8” hole through framing for con-
duit wiring. See Internal Blower on
page 8 for overall dimensions and
electrical requirements. See installa-
tion instructions provided with the
blower for mounting and installation
information.

IMPORTANT NOTE: 

Do not run or

remove blower electrical connections
through duct work.

I N S T A L L A T I O N

Install Ductwork

1)

Decide where the ductwork will

run between the hood and the
outside of the home. Your Wolf island
hood has a top discharge which will
run vertically.

IMPORTANT NOTE:

All hoods must

exhaust to the outdoors.

2)

When not installing an external

ventilator, always install a roof or
island cap. Connect 10" round metal
ductwork to the cap and work back
towards the hood location.

3)

Use duct tape to seal the joints

between the ductwork sections.

4)

Your Wolf island hood comes stan-

dard with a 10" round transition with
backdraft damper. It is recommended
that a backdraft damper be used in
all installations. 

IMPORTANT NOTE:

Do not use duct

smaller than 10". 

WARNING

To reduce the risk of fire, use
only metal ductwork.

Island Hood Top Transition

P

R O

S

E R I E S

I

S L A N D

H

O O D

I

N S T A L L A T I O N

Removing Island Hood Filter Bank

Summary of Contents for I363418

Page 1: ...P R O S E R I E S I S L A N D H O O D S I N S T A L L A T I O N I N S T R U C T I O N S...

Page 2: ...ust be completed by a qualified installer or service agency Before you begin installation read these instructions completely and carefully INSTALLER please retain these instructions for local inspecto...

Page 3: ...re 16 gauge stainless steel shell Transition with backdraft damper included Optional decorative rail assembly in stain less platinum brass or copper finish Hood must be specifically preordered and con...

Page 4: ...recommends installing a back draft damper in all installations included with hood In cold weather installations a back draft damper is necessary to minimize the backflow of cold air into the room 4 Wo...

Page 5: ...t Part number 805669 18 457 HEIGHT OF HOOD 34 864 DEPTH OF HOOD 36 914 WIDTH OF HOOD 30 TO 36 762 914 TO COOKING SURFACE COOKING SURFACE LOCATION OF ELECTRICAL CENTERED THROUGH TOP OF HOOD 30 TO 36 76...

Page 6: ...aming for con duit wiring See Internal Blower on page 8 for overall dimensions and electrical requirements See installa tion instructions provided with the blower for mounting and installation informa...

Page 7: ...and tighten into 2x4 framing DO NOT OVER TIGHTEN SCREWS 8 Connect the 10 round ductwork to the hood transition using sheet metal screws or duct tape 9 Make electrical connections See Install Wiring on...

Page 8: ...uch as a tag to the service panel P R O S E R I E S I S L A N D H O O D I N S T A L L A T I O N I N T E R N A L B L O W E R IMPORTANT NOTE Before turning the power on make sure the blower is in the OF...

Page 9: ...the switch 3 Wiring Remote Blower Follow wiring instructions at the blower as outlined in the particular blower installation instructions Black L1 to black white neutral to white or white to blue or...

Page 10: ...into place Lines of fil ters must run vertically and align with drip cups 5 Adjust filters to fill space by sliding filters left to right CAUTION Installing a duct cover assembly will impact all aspec...

Page 11: ...ods DUC12COVER54I 12 duct cover for 54 island hoods DUC12COVER66I 12 duct cover for 66 island hoods P R O S E R I E S I S L A N D H O O D A C C E S S O R I E S B L O W E R S Internal Blowers IBLOWER 1...

Page 12: ...rail for 54 island hoods RAIL 66 SS Decorative rail for 66 island hoods Platinum Finish RAIL 36 PLT Decorative rail for 36 island hoods RAIL 42 PLT Decorative rail for 42 island hoods RAIL 54 PLT Dec...

Page 13: ...t 800 332 9513 or check our website www wolfappliance com When calling for service you will need the island hood model and seri al numbers Both numbers are listed on the rating plate located on the le...

Page 14: ...14 CUT OUT FOR LOGO PLACEMENT BOTTOM EDGE OF HOOD FOLD LINE FOR LOGO PLACEMENT LEFT OUTER EDGE OF HOOD...

Page 15: ...Wolf Appliance Company LLC P O Box 44848 Madison WI 53744 800 332 9513 www wolfappliance com 805050 7 03...