Planning Information

60"

(1524) 

Dual Fuel Ranges

M O D E L S   D F 6 0 6 D G ,   D F 6 0 6 F ,   D F 6 0 6 C G ,   D F 6 0 4 C F   A N D   D F 6 0 4 G F

Dimensions in parentheses are in
millimeters unless otherwise specified.

5

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications

for overall dimensions, finished rough opening
dimensions and installation specifics.

IMPORTANT NOTE: 

Caution must be used in

planning the proper installation of the Wolf dual
fuel range to avoid any fires or damage to
adjacent cabinetry or kitchen equipment. Be
sure to follow minimum clearances established
in the finished rough opening dimensions as
shown in the illustration on page 4.

IMPORTANT NOTE: 

A minimum 10" (254) riser

is required for all 60" (1524) dual fuel range
models installed against a combustible surface.

A Wolf Pro ventilation hood or hood liner is

recommended. When installing a ventilation
hood, refer to the specific requirements of the
hood for the minimum dimension to countertop.
Also refer to the ventilation recommendation
charts in the Pro ventilation section of our
website, wolfappliance.com.

The 60" (1524) dual fuel range requires a

240/208 V AC, 60 Hz, 50 amp fused electrical
supply to operate the electrical portions of the
range. Locate electrical within the shaded area
shown in the illustration on page 4.

Wolf dual fuel ranges are designed with a

terminal block on the rear of the range. The
terminal block allows for a 3-wire or 4-wire
installation. For a 4-wire installation, the ground
strap from the unit to the terminal block must
be cut. Two concentric knockouts on the base
of the unit are provided to allow a certified elec-
trical contractor to wire the range directly to the
electrical supply. The terminal block will also
accept an appliance cord that is sized correctly
for the range’s voltage and amperage.

Wolf dual fuel ranges are designed to operate

on natural gas at 5" (12.5 mb) WC (water
column) pressure or LP gas at 10" (25 mb) WC
pressure. The minimum line pressure for natural
gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC
for LP gas. The maximum gas supply pressure
to the regulator should never exceed 14"
(34.9 mb) WC; .5 psi (3.5 kPa).

Wolf recommends the use of a 

1

/

2

" (13) I.D.

commercial type flex hose; this is the minimum
size that may be used. All plumbing to the flex
hose must be 

3

/

4

" (19) minimum I.D. pipe. 

IMPORTANT NOTE: 

A separate external gas

shut-off valve must be located near the range in
an accessible location. 

You must follow all National Electrical Code

and gas regulations. In addition, be aware of
local codes and ordinances when installing
your services.

Wolf dual fuel ranges using natural gas

function up to an altitude of 8,000' (2438 m)
without any adjustment. Natural gas and LP gas
installations from 8,000' (2438 m) to 11,000'
(3353 m) need the high altitude kit. Contact
your Wolf dealer for details. To obtain local
dealer information, visit the Showroom Locator
section of our website, wolfappliance.com.

Refer to the installation instructions

shipped with each Wolf product for detailed
specifications.

Summary of Contents for DF604CF

Page 1: ...tomize your range The electric ovens feature the Wolf exclusive dual convection system that delivers even temperature and airflow throughout Its two convection fans and four heating elements give the user convenience and superior control over ten different cooking modes Brilliant halogen lights illuminate the beautiful cobalt blue oven interiors Let Wolf the corporate companion and kitchen soul ma...

Page 2: ...burners with 950 Btu hr 3 kW delivered at simmer 9 200 Btu hr 2 7 kW burner with 325 Btu hr 1 kW delivered at simmer and melt feature Porcelain coated cast iron continuous top grates Ten cooking modes bake roast broil convection bake convection roast convec tion broil convection bake stone accessory required dehydrate accessory required and proof Pivoting hidden touch control panel Self cleaning o...

Page 3: ...leg caster covers High altitude conversion kit Accessories are available through your Wolf dealer To obtain local dealer information visit the Showroom Locator section of our website wolfappliance com S P E C I F I C A T I O N S Overall Range Width 601 8 1527 Overall Range Height to cooking surface 367 8 937 Overall Range Depth 291 2 749 Dual Stacked Sealed Surface Burners 15 000 Btu hr 4 4 kW bur...

Page 4: ...457 TO COUNTERTOP 30 min 762 TO 36 max 914 TO BOTTOM OF VENTILATION HOOD 36 min 914 COUNTERTOP TO COMBUSTIBLE MATERIALS 44 min 1118 FOR CHARBROILER ISLAND INSTALLATIONS 12 305 MINIMUM CLEARANCE FROM BACK OF RANGE TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP 0 0 TO NON COMBUSTIBLE MATERIALS 13 max 330 6 min 152 TO COMBUSTIBLE MATERIALS BOTH SIDES I N S T A L L A T I O N S P E C I F I C A T I O N S D I...

Page 5: ...al block allows for a 3 wire or 4 wire installation For a 4 wire installation the ground strap from the unit to the terminal block must be cut Two concentric knockouts on the base of the unit are provided to allow a certified elec trical contractor to wire the range directly to the electrical supply The terminal block will also accept an appliance cord that is sized correctly for the range s volta...

Reviews: