Installation Information
2-6
Anti-Tip Bracket Installation
Raise the unit to desired height using the rear leveling
casters and adjusting the front adjustable legs.
Try fitting the unit in place to verify the correct height.
Measure from the floor to the top of the range base
flange on the back of the unit. Add 1/8" to this dimen-
sion, mark this height on the wall behind the unit. This
will be the location of the bottom edge of the anti-tip
bracket. Try to center the mark between the cabinets.
For 48-inch and 60-inch ranges, care must be taken to
verify that the anti-tip bracket does not interfere with the
inner cavity supports. Locate a stud or other solid
mounting source, install the anti-tip bracket at the same
level as this line. Push the unit back, ensure the rear
base flange fits under the anti-tip bracket. (See Figure
3-3).
Unit Leveling
Rear Caster Adjustment
The Dual Fuel range has rolling casters, which allows
easy movement of the range by picking up on the front
of the unit. The range comes from the factory at an
overall height of 35-7/8" (from floor to the top of the
bullnose) before any height adjustment. The casters
allow for 2-1/8" height adjustment.
NOTE
:
Do not lift by oven door(s) handle.
To raise or lower rear caster, reach directly underneath
unit to rear caster and attach a 3/4” socket with an long
extension onto the adjusting bolt located on front of
caster assembly. Now, attach a drill or socket wrench
to extension and turn bolt left or right to raise or lower.
(See Figure 3-6)
Front Leveling Leg Adjustment
Dual Fuel ranges can be leveled at the front by turning
the front leveling legs as indicated in figure 3-6 The
legs allow for 2-1/8" height adjustment.
To raise or lower front leveling legs, use an adjustable
wrench to turn the leveling leg nut to the left or right to
raise or lower. (See Figure 3-6).
The stainless steel cover over the leveling leg floats up
or down to conceal the leveling leg from view. If level-
ing leg is still visible and the stainless steel cover is all
the way down, replace the stainless steel cover with a
longer version, available as a sales accessory.
ANTI-TIP BRACKET MUST BE ANCHORED TO
WALL BEHIND UNIT SO IT IS DIRECTLY ABOVE
THE BASE FLANGE OR APPLIANCE MAY TIP FOR-
WARD
SIDE PANEL
ANTI-TIP
BRACKET
BASE FLANGE
WALL
FLOOR
TO FLOOR
5 3/4" min.
Figure 3-4. Anti-Tip Installation
CASTERS ALLOW
2 1/8" HEIGHT ADJUSTMENT
FLOOR
Figure 3-5. Caster Height
Figure 3-6. Caster and Leveling Leg Adjustment
Summary of Contents for DF304
Page 2: ......
Page 12: ...D Du ua al l F Fu ue el l R Ra an ng ge e General Information 1 10 ...
Page 62: ...4 22 Component Access Removal D Du ua al l F Fu ue el l R Ra an ng ge e ...
Page 77: ...Technical Data D Du ua al l F Fu ue el l R Ra an ng ge e 6 1 SECTION 6 TECHNICAL DATA ...
Page 81: ...Wiring Diagrams D Du ua al l F Fu ue el l R Ra an ng ge es s 7 1 WIRING DIAGRAMS SECTIO N 7 ...