Downdraft Installation
14
BLACK TO BLACK
WHITE TO WHITE
GREEN TO GREEN
120 VAC LINE IN
Remote blower wiring.
REMOTE BLOWER
IMPORTANT NOTE:
For mounting and installation of the
remote blower, refer to the installation instructions for your
specific blower.
•
Mount a standard 120 V AC electrical box, with
3-pronged grounded receptacle, inside the cabinet or
adjacent cabinet. Make sure it is located within reach
of the 2
1
/
2
' (.8 m) power cord.
•
Run the appropriate power cable into the cabinet and
connect it to electrical box and outlet.
•
The remote blower may not exceed a 6.0 amp rating.
•
Run 2-wire plus ground power cable from the remote
blower to the electrical box on the remote blower
adapter plate.
•
Connect the downdraft wiring to the power cable from
the remote blower. Wire black to black, white to white
and green to green or bare wire. Refer to the illustration
below.
•
Replace the electrical box cover.
•
Plug the downdraft power cord into the outlet.
Wiring Connections
INTERNAL BLOWER
•
Mount a standard 120 V AC electrical box, with
3-pronged grounded receptacle, inside the cabinet or
adjacent cabinet. Make sure it is located within reach
of the 2
1
/
2
' (.8 m) power cord.
•
Run the appropriate power cable into the cabinet and
connect it to electrical box and outlet.
•
Plug the downdraft power cord into the outlet.