CONTROL MODULE INSTALLATION

Mark the center of the control module on the counter

top. Measure 2" (51) up (or left) and 2" (51) down (or

right) to locate holes for the mounting screws.

Carefully drill the three holes through the countertop.

Be careful not to damage or chip the countertop

surface while drilling.

Check the countertop thickness. Set the control

module in place and make sure the threaded studs are

long enough to allow the nylon thumbnuts to fully

engage. Thicker countertops may require that the holes

be partially counter-sunk from below.

Apply a bead of caulk all the way around the underside

of the control module to prevent liquids from reaching

the electrical connection or dripping through the holes

in the countertop. Position the control module.

From below the countertop, thread the two nylon

thumbnuts onto the studs of the control module and

hand tighten.

CONTROL MODULE CONNECTION

Connect the RJ45 connector cable to the back side of

the remote-mounted control module.

Connect the other end of the cable to the electrical

connection located on the right side of downdraft

assembly. Make sure that all connections are tight.

Refer to the illustration placed on the front of the

downdraft for the correct orientation of the RJ45

connector during installation into the downdraft

assembly.

Control Module

IMPORTANT NOTE:

The downdraft must be used with a

Wolf-approved control module and top cover.

The 2

3

/

8

" (60) x 6

5

/

8

" (168) remote-mounted control

module and stainless steel top cover are included with the

downdraft. Also included are mounting brackets, an RJ45

connector and mounting hardware.

The remote-mounted control module can be positioned

horizontally or vertically and located anywhere within 10'

(3 m) of the downdraft assembly and a minimum of 4"

(102) from the outer edge of any element or burner.

IMPORTANT NOTE:

Do not position the control module

where it will be in the way of cooking, where hot pans may

be placed or where hot liquids could be spilled on the

controls.

You will be required to drill three holes and connect the

control module to the downdraft assembly using the cable

provided. A 1" (25) diameter hole for the RJ45 connector

cable will be centered horizontally and vertically on the

back of the control module. Two

1

/

4

" (6) diameter holes for

the mounting screws will be located 2" (51) from the

center of the RJ45 connector cable hole.

To reduce the risk of burns or ignition of clothing by

reaching across the cooktop, the control module must

be mounted at least 4" (102) from an element or burner.

Summary of Contents for DD36I

Page 1: ...Downdraft Ventilation INSTALLATION GUIDE ...

Page 2: ...f instructions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Downdraft Ventilation 3 Installation Considerations 4 Downdraft Specifications 5 Downdraft Installation 9 Service Information 15 Features and specifications are subject to change at any time without notice Visit wolfappliance com specs for the most up to date...

Page 3: ...nce com This appliance must be installed in accordance with National Electrical Codes as well as all state municipal and local codes The correct voltage frequency and amperage must be supplied to the appliance from a dedi cated grounded circuit which is protected by a properly sized circuit breaker or time delay fuse The proper voltage frequency and amperage ratings are listed on the product ratin...

Page 4: ...ials necessary for proper installation Any required service must be performed by a Wolf authorized service center Installation Considerations Wolf downdraft systems can be used with all Wolf induc tion electric and gas cooktops except unframed models Wolf downdraft systems cannot be used with the steamer or fryer module and are not recommended for use with the electric grill module A downdraft can...

Page 5: ...mensions MODELS DD30I AND DD30R 23 8 60 30 762 91 16 230 261 4 667 11 2 38 DEPTH OF CHIMNEY 36 914 321 4 819 23 8 60 91 16 230 11 2 38 DEPTH OF CHIMNEY MODELS DD36I AND DD36R MODELS DD45I AND DD45R 451 2 1156 411 4 1048 23 8 60 91 16 230 11 2 38 DEPTH OF CHIMNEY ...

Page 6: ...stem and a Wolf cooktop you must allow for a minimum 251 8 638 flat counter space from front to back A countertop with a raised lip or backsplash may not allow enough space for proper installation 23 8 60 of flat countertop is required behind the cooktop and 13 4 44 is necessary between the back edge of the cooktop and inside of cabinet back Refer to the illustrations for specifications for a down...

Page 7: ...top is to be installed flush with cabinet face Installation Specifications For installation of a downdraft with a sealed burner rangetop refer to the sealed burner rangetop installation guide for rangetop dimensions rough opening and cabinet requirements Refer to the illustrations for specifications for a downdraft model DD30 or DD36 installed with a Wolf sealed burner rangetop model SRT304 or SRT...

Page 8: ...de cabinet or model DD45 in a 451 2 1156 wide cabinet the electrical outlet cannot be located on the back wall of the cabinet The outlet can be placed in an adjacent cabinet within reach of the power cord An access hole for the power cord must be drilled in the cabinet wall IMPORTANT NOTE A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation You must fo...

Page 9: ...ges of the countertop INSTALL THE DOWNDRAFT Set the downdraft into the opening Extend the leveling brackets to the floor of the cabinet so the downdraft sits straight Note that the leveling brackets can be removed and reattached in a different position The flange of the leveling bracket may have to face inward in tight cabinet installations Refer to the illustration below Secure the downdraft to t...

Page 10: ...o the illustration placed on the front of the downdraft for the correct orientation of the RJ45 connector during installation into the downdraft assembly Control Module IMPORTANT NOTE The downdraft must be used with a Wolf approved control module and top cover The 23 8 60 x 65 8 168 remote mounted control module and stainless steel top cover are included with the downdraft Also included are mounti...

Page 11: ...HVAC professional for specific installation and ducting applications Downdraft models with an internal blower have a 31 4 83 x 10 254 duct and remote blower models have a 31 4 83 x 14 356 duct Each can be transitioned to 8 203 or 10 254 round ductwork All downdrafts have an adjustable discharge For best performance 10 254 round ductwork is recom mended The downdraft will operate most efficiently w...

Page 12: ...ctwork IMPORTANT NOTE Use duct tape to seal the connection between the blower outlet and ductwork Support the weight of the ductwork as necessary to ensure sealed joints Adjustable Discharge Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around floor joists and other obstacles Three different discharge locations are available with side to side adjustme...

Page 13: ...l screws through the bottom flange to secure the bottom of the blower CLAMP CHANNEL NUT BLOWER COVER PLATE MOTOR PLUG SCREW Left or right side discharge Blower Discharge Adjustment DOWN DISCHARGE ADJUSTMENT Adjusting the down discharge left or right will keep the blower discharge in the down position but allows some side to side adjustment Follow these steps if the position of the blower discharge...

Page 14: ...y not exceed a 6 0 amp rating Run 2 wire plus ground power cable from the remote blower to the electrical box on the remote blower adapter plate Connect the downdraft wiring to the power cable from the remote blower Wire black to black white to white and green to green or bare wire Refer to the illustration below Replace the electrical box cover Plug the downdraft power cord into the outlet Wiring...

Page 15: ... your gas range by calling a Wolf authorized service center To obtain the name and number of a Wolf authorized service center check the contact support section of our website wolfappliance com or call Wolf customer service at 800 332 9513 When calling for service you will need the model and serial numbers of the downdraft This information is found on the product rating plate located above the blow...