![Wolf CWL-2-400 Installation And Operating Instructions Manual Download Page 23](http://html1.mh-extra.com/html/wolf/cwl-2-400/cwl-2-400_installation-and-operating-instructions-manual_992186023.webp)
7
Starting appliance
7.1
Switching appliance on and off
Switching on:
–
Switching on the mains power:
1. Connect the 230 V power plug to the electric system.
2. During the startup of the appliance, the version of the software is displayed.
If the appliance has been without power for a long time (more than approx. 1
week), you will have to reset the correct language, time and date in setting
menu .
3. The appliance will then operate immediately after this according to the mode
of the multiple switch. If no multiple switch is connected then the appliance
operates always in mode 1.
Switching off:
–
Switching off mains power:
1. Pull the 230 V power plug from the electric system; the appliance is now free
of voltage.
2. Nothing is now shown on the display.
Warning!
When working on the appliance, always first take the voltage from the appliance by
pulling the power plug.
7.2
Setting the air flow
Good ventilation contributes to healthy air in the home, optimal comfort and the proper functioning of the
installation.
The air flows of the appliance have been set in the factory as follows 50, 100, 200 and 300 m
3
/h. The
performance and the energy consumption of the appliance depend on the pressure drop in the duct
system, as well as on the filter resistance. If these conditions are not complied with, the air flow rate of the
higher mode will automatically be adjusted.
Changes can be carried out in the settings menu .
Go in the settings menu to steps 1.2 to 1.4 to adjust the air flow.
Please note!
The highest demanded ventilation mode has priority. If the external multiple switch is set to mode 3, then
the ventilation mode cannot be adjusted to a lower mode on the main screen.
An exception to this is ventilator mode 0. If mode 0 is chosen on the display: control from other switches,
sensors, etc. is not possible.
For connected CO
2
sensors the air flow will be steplessly controlled between mode 1 and 3 depending on
the measured PPM values: for a connected humidity sensor the air flow will be switched to mode 3 when
this is switched on.
7.3
Other settings for installer
In addition to the air flow, it is also possible to change other settings of the appliance; for an overview of
these settings of a standard appliance (
®
Setting values standard appliance page 46 ) and appliance
Starting appliance
7100833_202010
WOLF GmbH | 23