Page 8
Induction Cooktop (CTI) Series
Induction Cooktop (CTI) Series
Troubleshooting Guide
5-8
#821684 - Revision B - March, 2013
LED board failure.
Action: Perform LED test #1 and if all
LEDs work, reset error.
Action: If one of the LEDs fails to illuminate
change the Glass Assy.
Induction generator failure.
Action: Change affected generator board.
Induction generator failure.
Action: Change affected generator board.
1. Induction generator failure.
Action: Perform Heatsink test #4 and if
appears ok, reset error and test operation
2. If error returns.
Action: Change affected generator board.
Effected burner is not
available.
The effected burner will
shutdown.
The effected burner will
shutdown.
The effected burner will
shutdown.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
E30
E31
E32
E33
E34
E40
E41
E42
E43
E44
E45
E50
E51
E52
Generator 1:
Burner (F,FR,FC)
‘ON LED’ Failure
Generator 1:
Burner (R,RR,RC)
‘ON LED’ Failure
Generator 2:
Burner (RL) ‘ON
LED’ Failure
Generator 2:
Burner (FL) ‘ON
LED’ Failure
Generator 3:
Burner (RR) ‘ON
LED’ Failure
Generator 1:
Burner (R,RR,RC)
sensor shorted.
Generator 2:
Burner (RL) sensor
shorted.
Generator 3:
Burner (RR) sen-
sor shorted.
Generator 1:
Burner (R,RR,RC)
sensor open.
Generator 2:
Burner (RL) sensor
open.
Generator 3:
Burner (RR) sen-
sor open.
Generator 1:
Open heat sink
thermistor.
Generator : Open
heat sink thermis-
tor.
Generator 3:
Open heat sink
thermistor.
ERROR
PRIORITY
NOTES
POSSIBLE SOURCE(S) OF
FAILURE / ACTION REQUIRED
DISPLAYED
ERROR #
ERROR
CONDITION