Page 4
Induction Cooktop (CTI) Series
Induction Cooktop (CTI) Series
Troubleshooting Guide
5-4
#821684 - Revision B - March, 2013
SOFTWARE VERSION (Seventh Test)
1.
To enter Software Version, press the “+” key of the 3000W element controls. The 3000W bar graph will show 15
LEDs.
2.
The Timer display will illuminate the software version (scrolling if necessary).
3.
Press the “-” key of the 3000W inductor to step back to the Power Cycling Information.
LAST KNOWN STATE (Eighth Test)
All priority 1 errors will take precedence over priority 2 errors. If there are no known priority 1 errors recorded, the
software will record the LKS of the last recorded priority 2 error. If there are no priority 1 or 2 errors, the Timer dis-
play will continue to display LS. If a priority 1 error should occur, the LKS would be recorded and not any subse-
quent priority 2 error’s LKS.
1.
To enter Last Known State, press the “+” key of the 3000W element controls. The controls will light up the LEDs
of the last known state.
2.
The 3-digit display will display a “LS” right justified in the window.
3.
Press the “-” key of the 3000W Inductor to step back to the Software Version.
4.
Press the “+” key of the 3000W inductor will step forward to the LED TEST.