7
I N S TA L L AT I O N
I N S T R U C T I O N S
229 mm*
min
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
457 mm
489 mm
COOKTOP CUT-OUT
DEPTH
914 mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
330 mm
max
762 mm
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
610 mm
min
*Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 457 mm above countertop.
**Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 457 mm above countertop.
102 mm
254
mm
89 mm
E
95 mm
min
G
762 mm OVEN OPENING
737 mm
COOKTOP
CUT-OUT WIDTH
737 mm
COOKTOP CUT-OUT WIDTH
FRONT OF COUNTERTOP
64 mm
min
489 mm
COOKTOP
CUT-OUT DEPTH
838 mm
RECOMMENDED
CABINET WIDTH
762 mm
min
64**
mm
64 mm
min
Overall Dimensions
Countertop Cut-Out
533 mm
OVERALL
DEPTH
762 mm
OVERALL WIDTH
102 mm
I N S TA L L AT I O N
S P E C I F I C A T I O N S
The illustrations below provide the overall
dimensions, countertop cut-out and installation
specifications for Model ICBCT30G/S.
IMPORTANT NOTE:
838 mm wide cabinets are
recommended for installation of Model
ICBCT30G/S.
A Wolf 762 mm single built-in oven may be
installed below Model ICBCT30G/S. For this
installation, unless you are using cabinets
deeper than 610 mm, it is recommended that
the electrical and gas supply be placed in the
base cabinet to the right of the oven. Refer to
installation instructions provided with the built-
in oven for additional specifications.
If the Model ICBCT30G/S is installed above
cabinets, the gas and electrical placement is not
critical. A grounded outlet needs to be placed
within 1.2 m of the right rear of the cooktop.
IMPORTANT NOTE:
When multiple cooktop
units are installed side by side, refer to the
countertop cut-out dimensions on page 9.
M O D E L I C B C T 3 0 G / S
D I M E N S I O N S
Overall Width
762 mm
Overall Height
102 mm
Overall Depth
533 mm
Recommended
Cabinet Width
838 mm
Minimum Cabinet Depth
578 mm
Minimum Height Clearance 102 mm
Cut-Out Width
737 mm
Cut-Out Depth
489 mm
Unit dimensions may vary to ±3 mm.
I N S T A L L A T I O N S P E C I F I C A T I O N S – M O D E L I C B C T 3 0 G / S
Note A
Note B
Note A:
Side clearances. If the distance
measured from the periphery of the
nearest burner to any vertical surface
is less than 200 mm, the surface shall
be protected in accordance with
clauses 5.12.1.1. & 5.12.1.2 of AS5601.
Note B:
The rangehood fitted above the
cooktop must be installed according to
the installation instructions for the
rangehood. A minimum distance of
750 mm is required for a range hood
and 750 mm for an exhaust fan
.
533 mm
OVERALL
DEPTH
762 mm
OVERALL WIDTH
102 mm
COOKTOPS installation manual:Intl Gas Cooktops Install 31/3/10 2:24 PM Page 7