6
I N S TA L L AT I O N
S P E C I F I C A T I O N S
The illustrations below provide the overall
dimensions, countertop cut-out and installation
specifications for Model ICBCT15G/S.
For Model ICBCT15G/S, the gas service may be
supplied through the floor if the cooktop is not
installed above an oven. Refer to the illustration
for specifics on placement of gas and electrical.
E
102 mm
G
381 mm
381 mm
381
mm
LOCATION OF GAS SUPPLY
MAY ALSO EXTEND 127 mm ON
FLOOR FROM BACK WALL
178 mm*
min
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
356 mm
COOKTOP CUT-OUT
WIDTH
356 mm
COOKTOP CUT-OUT
WIDTH
838 mm
RECOMMENDED
CABINET WIDTH
457 mm
NOTE: Application shown allows for installation of two 381 mm modules side-by-side with 838 mm recommended cabinet width. 457 mm
recommended cabinet width for installation of single 381 mm cooktop or module. *Minimum clearance from both side edges of cooktop cut-out
to combustible materials up to 457 mm above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up
to 457 mm above countertop.
489 mm
COOKTOP CUT-OUT
DEPTH
64 mm
min
914 mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
330 mm
max
762 mm
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
64**
mm
127
mm
LOCATION OF GAS
SUPPLY MAY ALSO
EXTEND 127 mm ON
FLOOR FROM BACK WALL
FRONT OF COUNTERTOP
64 mm
min
489 mm
COOKTOP
CUT-OUT DEPTH
W O L F
G A S C O O K T O P S
Overall Dimensions
Countertop Cut-Out
381 mm
OVERALL WIDTH
533 mm
OVERALL
DEPTH
102 mm
M O D E L I C B C T 1 5 G / S
D I M E N S I O N S
Overall Width
381 mm
Overall Height
102 mm
Overall Depth
533 mm
Recommended
Cabinet Width
838 mm
Minimum Cabinet Depth
578 mm
Minimum Height Clearance 102 mm
Cut-Out Width
356 mm
Cut-Out Depth
489 mm
Unit dimensions may vary to ±3 mm.
I N S T A L L A T I O N S P E C I F I C A T I O N S – M O D E L I C B C T 1 5 G / S
IMPORTANT NOTE:
When multiple cooktop
units are installed side by side, refer to the
countertop cut-out dimensions on page 9.
533 mm
OVERALL
DEPTH
381 mm
OVERALL
WIDTH
102 mm
Note A
Note B
Note A:
Side clearances. If the distance
measured from the periphery of the
nearest burner to any vertical surface
is less than 200 mm, the surface shall
be protected in accordance with
clauses 5.12.1.1. & 5.12.1.2 of AS5601.
Note B:
The rangehood fitted above the
cooktop must be installed according
to the installation instructions for
the rangehood. A minimum
distance of 750 mm is required for a
range hood and 750 mm for an
exhaust fan
.
COOKTOPS installation manual:Intl Gas Cooktops Install 31/3/10 2:24 PM Page 6