Time programs
17.2 Symbols for possible changes using the rotary selector
Symbol
Function
The automatic timer switches the
heating circuit
on and off at the programmed switching times.
Within the switching times, the heating circuit heats up to the set room temperature (day temperature) with the
enabled room influence or in accordance with the set heating curve.
The automatic timer switches the
mixer circuit
on and off at the programmed switching times.
Within the switching times, the mixer circuit heats up to the set room temperature
(day temperature) at the enabled room influence or in accordance with the set heating curve.
The
DHW cylinder
is heated up to the set DHW temperature within the switching times.
The
DHW circulation pump
(if installed) is only switched on within the switching times.
In automatic mode with the
CWL Excellent
, the system only switches between "Std ventilation" within the
switching time and "reduced ventilation" outside the switching time.
Party mode
In party mode, the time and date are entered at which the heating system goes into continuous heating mode.
The time and date at which the heating system returns to the previously selected operating mode are also
entered.
(see chapters "Heating circuit status page" and "Mixer status page", section "Changing the mixer circuit
operating mode")
Setback mode
In setback mode, the time and date are entered at which the heating system goes into continuous economy
mode. The time and date at which the heating system returns to the previously selected operating mode are
also entered.
(see chapters "Heating circuit status page" and "Mixer status page", section "Changing the mixer circuit
operating mode")
Permanent heating mode
In permanent heating mode, the heating system is continuously on.
The heating system heats up to the set room temperature (day temperature) or in accordance with the settings
of the heating curve.
In economy mode, the heating system heats up to the set economy temperature.
In standby mode, the heating system and DHW heating are switched off.
The DHW circulation pump (if installed) is switched off.
The frost protection function is enabled.
The heating system pumps are switched on at regular intervals to prevent the equipment from seizing up.
Mo
Su
Weekdays