3064202_201602
31
Time programs
Symbol
Function
DHW mode
In DHW mode, the BM-2 programming unit keeps DHW heating switched on continuously.
1 x
The special function 1x DHW bypasses the programmed switching times and heats up the DHW cylinder once,
for one hour, to the set DHW temperature.
The system targets the set air volume of parameter CWL1. Temporary moisture protection can only be enabled
by entering the start and end times. Once this time has elapsed, the program switches back to the previously
selected operating mode.
During "reduced ventilation", the ventilation unit runs permanently in accordance with the settings in parameter
CWL2.
During "Std ventilation", the ventilation unit runs permanently in accordance with the settings in parameter
CWL3.
The system targets the set air volume of parameter CWL4. Temporary intensive ventilation can only be enabled
by entering the start and end times. Once this time has elapsed, the program switches back to the previously
selected operating mode.