3064202_201602
23
Default settings overview
16 Default settings overview
A list of all default settings can be found below:
Parameter
Setting range
Factory setting
Chapter
Heating appliance – DHW mode
ECO / Comfort
ECO
16.1.1
Heating circuit
16.2
Mixer 1 - 7
16.2
Language
Deutsch
16.3
Time
00:00 - 24:00 h
16.4
Date
01/01/2011 - 31/12/2099
16.5
Winter/summertime
Auto/manual
Auto
16.6
Min. backlighting
5 % - 15 %
10 %
16.7
Screensaver
ON / OFF
OFF
16.8
Key lock
ON / OFF
OFF
16.9
User interface
Extended /
Simplified
Extended
16.10
The following is a list of all default settings for
heating circuit and mixer circuit 1-7
Economy factor in economy mode
0 - 10
4
16.2.1
Winter/summer changeover
0 °C - 40 °C
20 °C
16.2.2
ECO / ABS
-10 °C - 40 °C
10 °C
16.2.3
Day temperature (BM-2 in wall mounting
base and room influence enabled)
5 °C - 30 °C
20 °C
16.2.4
Room influence (BM-2 in wall mounting
base)
ON / OFF
OFF
16.2.5
16.1 Heating appliance
16.1.1 DHW operating mode
Setting range: ECO / Comfort
Factory setting: ECO
The DHW operating mode function only applies to combi boilers. The Comfort setting activates a DHW quick start
and keeps the heating appliance at the right temperature to ensure rapid DHW heating. In the ECO setting, the
heating appliance is not brought up to temperature until the tap is opened.
14:12
20.01.13
Heating appliance
Heating circuit
Mixer 1
Language
English
Default settings
14:12
20.01.13
DHW operating mode
Value:
Comfort
Heating appliance
14:12
20.01.13
Main menu
Display
Default settings
Time programs
Contractor level
Entry