Operating manual GMV-B
Page 12 of 28
B0823
Solenoid:
Voltage
24 VDC or 230 VAC
Duty cycle
Version "A"
100%
Version "B"
25%
Version "C"
100%
Version "D"
15%
Amperage
with 24 VDC
Version "A"
max. 1,34 A
Version "B"
max. 4,20 A
Amperage
with 230 VAC
Version "C"
max. 0,16 A
Version "D"
max. 0,88 A
Protection type
DIN EN 60529
IP65
Insulating material class
F
Plug connector
DIN EN 175301-803, shape A
Pneumatic drive assembly:
Air pressure of the drive assembly
3 ... 6 bar
Compressed air quality
acc. to ISO 554, class 5
3/2-directional control valve:
Power rate
5 W
Relative duty factor
100% ED
Protection type
DIN EN 60529
IP65
Plug connector
DIN EN 175301-803, shape BI
Voltage
24 VDC
When connecting inductive or capacitative loads, install proper
protection circuits! (Diode, RC-circuit, varistor)
3.5.4 Level monitoring F
Voltage
10 … 30 VUC
Amperage
max. 0,25 A
Protection type
DIN EN 60529
IP67
Connection
Plug connector M8x1, 3-pin
Output
NC contact
3.5.5 Function control 1
Voltage
10 … 30 VDC
Load current
≤200 mA
Protection
DIN EN 60529 IP67
Connection
Plug connector M8x1, 3-pin
Output
PNP NO contact