GMG-LEZ Operation manual
Page 11 of 37
B0840
Filling connector "G"
Closing nippl
Filling connector "C"
1)
Button head lubricating nipple
DIN 3404 - M22
Auxiliary for filling connector "G":
Coupling
954.002-09
(pmax = 35 bar)
Filling connector "A"
1)
Hydraulic-type lubricating nipple
DIN 71412 - AG1/4
Filling connector "G"
Closing nippl
Filling connection
Hydraulic-type lubricating nipple DIN 71412
Button head lubricating nipple DIN 3404
Lock nipple
A
G
1
/4
C
G
1)
not suitable for oil
3.5.3 Level monitoring (option)
The technical data of the (optional) level monitoring unit is as follows:
Supply voltage
24 VDC
Switching current
max. 80 mA
Switching power
max. 1.5 W
Temperature range
-20
… +60 °C
Contact function
PNP opener
When connecting inductive or capacitive loads, the relevant sup-
pressor circuits (diode, RC element, varistor) need to be provided for!
3.5.4 Control
The technical data of the (optional) control is as follows:
Power input
1.7 W
Supply voltage / target
24 VDC
Supply voltage
18
… 30 VDC
Voltage at inputs
24 VDC
Response time of inputs
200 ms
Input resistance
4 k
Ω
Temperature range
-
20 … +60 °C
Alarm output
100 mA / 24 VDC / 2 W
Filling connector:
Filling connector: