Ambient temperature
+16 °C to a maximum of +32 °C
Maximum humidity
80 % relative humidity without condensation.
Do not use unit outdoors.
Degree of protection
IP X0
Installation surface /
water spray
The device must be placed and levelled on a horizontal, sturdy,
water-resistant, and heatproof base.
The device must not be cleaned using a water jet. The device must
be installed where it is protected against water spray. The device
must not be located on a surface that is sprayed or cleaned with
a water hose, steam jets, steam cleaner, or similar devices.
Installation clearances
For operating, service and safety reasons the device should be
installed with a clearance of no less than 50 mm between the back
of the machine and the wall. If possible, there should be a clearance
of 50 mm to the sides. (Lateral connection WMF coffee machine and
WMF Cup&Cool not taken into account.)
Ventilation
If the possibility of ventilation is limited, adequate ventilation
must be provided. Ventilation must be designed according to
the installation situation. (e.g. device on legs, active ventilation,
additional air vents / openings in counter area, etc.). Ventilation
openings must not be covered.
These specifications for the electrical connection and the standards quoted
apply for connecting the device in EU countries. It may be necessary to also
observe additional country-specific regulations. Outside the EU countries
acceptance of the standards quoted is to be checked by the legal entity or
natural person who wishes to use the machine.
The local power supply must be constructed according to IEC 364. To improve
safety, the device should be fitted with an FI 30 mA earth leakage current circuit
breaker complying with EN 61008. Near the device or about 30 cm below the
counter top there should be a shockproof socket as a single-phase connection
installed locally on the rear or side wall of the counter substructure or a country-
specific single-phase socket. The socket is part of the on-site installation.
The mains cable must not come into contact with hot surfaces. If the mains cable
for this device is damaged then it must be replaced by our service personnel or