WL-G930 Series Router User Manual
56
Parameter
Instruction
receiving SMS from the number in phone book.
M2M Control: it’s not ready.
Alarm Action
Digital Output initiates when there is an alarm.
Selected from “OFF”, “ON”, “Pulse”.
OFF: Open from GND when triggered.
ON: Short contact with GND when triggered.
Pulse: Generates a square wave as specified in the pulse mode
parameters when triggered.
Power on
Status
Specify the digital Output status when power on.
Selected from OFF and ON.
OFF: how high(0V).
ON: high lever(4.8-5.0V)
Keep On
Available when digital output Alarm On Action/Alarm Off Action
status is ON, input the Digital Output keep on status time.
Input from 0 to 255 seconds. (0=keep on until the next action)
Delay
Available when enable Pulse in Alarm On Action/Alarm Off Action.
The first pulse will be generated after a
“
Delay
”
.
Input from 0 to 30000ms. (0=generate pulse without delay)
Low
Available when enable Pulse in Alarm On Action/Alarm Off Action.
In Pulse Output mode, the selected digital output channel will
generate a square wave as specified in the pulse mode parameters.
The low level widths are specified here.
Input from 1 to 30000 ms.
High
Available when enable Pulse in Alarm On Action/Alarm Off Action.
In Pulse Output mode, the selected digital output channel will
generate a square wave as specified in the pulse mode parameters.
The high level widths are specified here.
Input from 1 to 30000 ms.
Output
Available when enable Pulse in Alarm On Action/Alarm Off Action.
The number of pulses, input from 0 to 30000. (0 for continuous pulse
output)
SMS Trigger
Content
Available when enable SMS Control in Alarm Source.
Input the SMS content to enable
“
Alarm On Action
”
by SMS (70
ASIC II char max).
SMS Reply
Content
Input the SMS content, which will be sent after DO was triggered.
(70 ASIC II char max).
Number 1
SMS receiver phone number.
Number 2
SMS receiver phone number.
Step 3 Please click ”save” to finish.