WL-G930 Series Router User Manual
54
Parameter
Instruction
Under EVENT_COUNTER mode, if first pulse shape and last pulse
shape are not the same level, WL-G930 will trigger alarm according
to Counter Action setting.
Counter Trigger Available when DI under Event Counter mode
Input from 0 to 100. (0=will not trigger alarm)
It will trigger alarm when counter reaches this value. After triggering
alarm, DI will keep counting but no trigger alarm again.
Counter Period
It’s a reachable IP address. Once the ICMP check is failed, GRE will
be established again.
Counter
Recover
it will re-count after counter trigger alarm. The value is 0~30000(*100ms).
0 means no counter.
Counter Action
HI_TO_LO and LO_TO_HI is available when DI under Event
Counter mode.
In Event Counter mode, the channel accepts limit or proximity
switches and counts events according to the ON/OFF status. When
LO_TO_HI is selected, the counter value increase when the
attached switch is pushed. When HI_TO_LO is selected, the counter
value increases when the switch is pushed and released.
Counter Start
Available when DI under EVENT_COUNTER mode. Start counting
when enable this feature.
SMS Alarm
The alarm SMS will send to specified phone group.
Each phone group include up to 2 phone numbers.
SMS Content
70 ASCII Char Max
Number 1
SMS receiver phone number.
Number 2
SMS receiver phone number.
Step 2 Please click ”save” to finish.
OFF Mode
DI from high level 3.3~5V to low level 0V will be triggered.
ON Mode
Data input from low level 0V to high level 3.3~5V will be triggered.