WIZ140SR/WIZ145SR Datasheet
7
None Odd Even
[Flow control]
0 1
2
None Xon/Xoff RTS/CTS
RnOC None
Get
Data Packing Condition ‘Char’
n
: channel number( 0 ~ 3)
WnOC xx
Set
Data Packing Condition Char
n
: channel number( 0 ~ 3)
ex) if value is 0x0D, then ‘0’’D’
RnOS None
Get
Data Packing Condition ‘Size’
WnOS
0 ~ 255
Set
Data Packing Condition ‘Size’
n
: channel number( 0 ~ 3)
RnOT None
Get
Data Packing Condition ‘Time’
n
: channel number( 0 ~ 3)
WnOT
0 ~ 65535
Set
Data Packing Condition ‘Time’
n
: channel number( 0 ~ 3)
RnOI None
Get
Inactivity Time value
n
: channel number( 0 ~ 3)
WnOI
0 ~ 65535
Set
Inactivity Time value
n
: channel number( 0 ~ 3)
표
2 Serial Command Code Table
3.2.3 Reply code(Direction: MODULE -> Serial device)
Reply
Meaning
E
Serial command mode Start
S
Command Success
F
Command Fail
1
Invalid command
2
Invalid parameter
표