Änderungen vorbehalten!
Subject to change without notice!
Blatt/
sheet
PM.7.002883.EN.36
Datum/
date
23.01.2013
Stand/
version
J-31.07.2017
Geprüft/
approved
WAT/MZE
Overspeed governor EOS
Operating instructions
4.6.5
Error-codes
The different error codes are visualised with the
LEDs TTS1, TTS2 and Change UNIT or with the
encoder output if no other option of the encoder is
ordered.. The errors are shown as morse-code.
Find the table with the error-codes on the next
page. The error-codes are shown like this: long
flashes are “-”, short flashes are “ . “. Warnings are
only shown with the LEDs TTS1 and TTS2.
Morsecode
Blinkcode
Warnings
Type
A
.-
UCM contact position limit reached
UCM
I
..
UCM tripping position limit reached
M
--
UCM contact speed limit reached
N
-.
UCM tripping speed limit reached
F
..-.
contact speed limit reached (overspeed)
overspeed
Z
--..
tripping speed limit reached (overspeed)
D
-..
advanced tripping limit reached (overspeed)
K
-.-
advanced contact limit reached (overspeed)
O
---
contact acceleration limit reached
acceleration
G
--.
tripping acceleration limit reached
B
-…
life time warning
lifetime
R
.-.
sychnro plate (solenoid unit) not in neutral position
warnings
S
…
encoder problem
U
..-
bus communication problem
W
.--
remote trip input was activated
remote trip
Morsecode
Blinkcode
Errors
Type
C
-.-.
encoder error
errors
H
….
end of life reached
J
.---
enable movement signal error
L
.-..
board temperature too high or low
P
.--.
internal hardware error
Q
--.-
bus communication error
V
…-
internal function check error
X
-..-
DIP switch setting wrong or
X
-..-
ENMOVE signals different
Y
-.--
input signal error