Overspeed governor EOS
Operating instructions
4.3.11
DIP switches
With the 4 single switches (S1/1 to S1/4) the sole-
noids can be switched separately (S1/2, S1/3) and
the operating mode can be changed from “normal
operation” to “construction time use” (S1/1, S1/4).
Do not turn on/off S1/1 and S1/4 unless power is
off.
When S1/2 and S1/3 are switched off simultaneous-
ly, a reset operation will be executed.
4.3.12 LEDs
Some LEDs are used to show the state of the EOS
inputs and outputs:
The other LEDs show the status of the board and
solenoids:
*) flashing in the same interval but with only short
flashing of the LED indicates that the mechanical
brake has reached its wear limit.
**) if triggered via TRIP the LEDs show which side of
the solenoids has tripped by flashing briefly.
4.3.13 Bus interface
This interface (X6) is reserved for future extensions.
S1/1 S1/2 S1/3 S1/4 Function
OFF
OFF
OFF
OFF
“construction time use”
ON
OFF
OFF
ON
“normal operation”-mode
OFF
-
-
ON
prohibited state
ON
-
-
OFF
prohibited state
-
OFF
OFF
-
both solenoids on
-
ON
-
-
Solenoid 1 off
-
-
ON
-
Solenoid 2 off
LED
Function
POWER
™
no power supply
˜
power supply OK
CHANGE UNIT
™
board OK
ð
internal error*
˜
check power supply
TTS1, TTS2
™
normal operation**
ð
in construction time use:
TTS1 flashes every second
TTS2 flashes every meter
˜
start up operation
SAFETY
™
safety circuit opened
˜
safety circuit closed
TRIP
™
no input signal at X5/4
˜
TRIP input signal at X5/4
COIL
™
solenoids (coils) off
ð
only 1 solenoid (coil) off
˜
both solenoids energized;
pulley rotation possible
ENMOVE
™
no input signal at X5/3
no input signal at X5/3
˜
ENM1 input sign. at X5/3
RESET
™
no input signal at X5/5
˜
RESET input signal at X5/5
MOVEMENT
LIMITED
™
contact X3/1-X3/2 opened
˜
contact X3/1-X3/2 closed
LED
Function
™
LED off
ð
LED flashing
˜
LED on
LED flickering
ON
switch on
standing position
é
headfirst position
ê
OFF
switch off
standing position
ê
headfirst position
é
-