8.5.1 Opening the lock with the combination interlock feature activated (duality principle)

When user combinations are employed to open the lock it is necessary to enter two different user combinations,
including the associated user number (see example below).

Once the first user combination has been entered a beep will sound every five seconds for a period of 60
seconds. If the second user combination is not entered within this 60-second limit, then the entry will be
discarded and both user combinations will have to be entered again.

Example

     °

Button       for UNo. 1
Button       for UNo. 2

etc. through to     button
for UNo. 5

°

°

Enter first user number e.g. 1
Enter first user combination e.g.
Enter second user number e.g. 4
Enter second user combination e.g.

Cancel

OK = green LED
blinks once and low-
high tone sounds.
Error = 3 high-pitched
tones and red LED
lights.

9

8

7

6

5

4

Function

Operation, button(s)

Response

Comments

Initiate programming
Select P - No. 2
Confirm the entry
Enter 6-digit master combination, e.g.
Confirm the entry
Entry
Confirm the entry

Cancel

8.5.2 Deactivating the combination interlock function (duality principle)

Possible only with the electronic lock open and only with the master combination.

Green LED blinks once

OK = green LED blinks once
and low-high tone sounds.
Error = 12 high-pitched
tones and red LED lights.

Function

Operation, button(s)

Response

Comments

Once a silent alarm has been activated, the lock will open in the same way as if the normal master combination or a user
combination had been entered. This also applies to any programmed delay period or combination interlock.

Enter UNo. and the master or user combination for silent alarm

°

° Button     for UNo. 0  (master combination)
  Button      for UNo. 1  (user combination)
  Button      for UNo. 2  (user combination)

etc. through to

  Button      for UNo. 5  (user combination)

Entering the combination:

9. Triggering a silent alarm

To trigger a silent alarm, increase by 

1

 the final digit of your master or user combination.

Example:

Master or user combination      Master or user combination for silent alarm

1 2 3 4 5 6

1 2 3 4 5 7

1 2 3 4 5 9

1 2 3 4 5 0

Summary of Contents for Insys 7202

Page 1: ...ing your own master combination see Section 8 1 Do not use any personal data for your new master or user combination The maximum permissible interval between any two keypad entries is 30 seconds If this limit is exceeded then the entire procedure will have to be repeated from the beginning 1 1 Explanation of terms The following terms and symbols are used User number User number abbreviated UNo UNo...

Page 2: ...ct the entry In this case you will have to repeat the entire entry sequence Correct entry is confirmed with a tone The green LED will now blink and the electronic lock is cleared for opening for a period of 12 seconds The door to the safe can now be unlocked using the keypad lever and the fingertip grip The green LED will blink at a 3 second interval for as long as the electronic lock is open The ...

Page 3: ...the 6 digit master or user combination e g Confirm the entry Enter the new 6 digit user combination e g Confirm the entry Enter the new 6 digit user combination again to confirm Confirm the entry Cancel A maximum of 5 user combinations can be programmed 9 8 7 6 5 4 The previous user combination will be retained if there is an error in programming UNo 1 UNo 5 Green LED blinks once OK green LED blin...

Page 4: ...1 minute release period Timed delay period of 11 to 59 minutes 2 minute release period 8 3 Programming a timed delay period Possible only with the electronic lock open and only with the master combination Initiate programming Select P No 3 Confirm the entry Enter 6 digit master combination e g Confirm the entry Enter timed delay period e g 1 minute Confirm the entry Cancel 1 minute to 59 minutes G...

Page 5: ...l blink every 30 seconds and the keypad will not respond to any entries at all Oncetheprogrammedtime lockperiodhaselapsedtheelectronic lock can be opened using either the master combination or a user combination The time lock period will run to completion once only after it has beenentered Theelectroniclockwillthenbereleasedforopening until such time as a new time lock period is programmed When th...

Page 6: ...nitiate programming Select P No 2 Confirm the entry Enter 6 digit master combination e g Confirm the entry Entry Confirm the entry Cancel 8 5 2 Deactivating the combination interlock function duality principle Possible only with the electronic lock open and only with the master combination Green LED blinks once OK green LED blinks once and low high tone sounds Error 12 high pitched tones and red L...

Page 7: ...ace the batteries or install them properly Keypad lever cannot be moved even though a valid combination has been entered correctly Batteries are too weak to release the electronic lock Replace the batteries Green LED blinks at 5 second intervals the electronics do not respond to any keypad entries A timed delay period has been inadvertently entered See notes at Sections 7 3 and 8 3 1 12 signal ton...

Reviews: