Wittkopp GATOR 2000 Installation Instructions Manual Download Page 13

13

Installation instructions Gator

Rel. 1.2

7.3.2 Dimensions lock Gator 3010 - long connection with mechanical emergency lock

Installation example

Area around the
unlocking lever must
be protected
especially.

Gator 3010

9,1

66,5

88

116

25,4

41

60,7

(X)

66,5

88

Ø 7

Ø

7

Hub/stroke 12

13,5

58,3

41

60,7

3

34

25

Mechanical
emergency lock

7.4 Dimensions lock Gator 5000/6000/8000/9000

7.4.1 Bolt stroke

Hub von  9 - 15 mm verstellbar/

Stroke adjustable from 9 - 15 mm

66,5

88,5

103,4

41

60,7

Ø 6,5

7,8

14,2

7 12

4

34

15

M

4

25,4

35,7

Attention: Bolt stroke only has to be adjust when 

                 lock bolt is completely moved into lo-

                 cking position.

Adjustment screw for
bolt stroke:
Stroke length can be redu-
ced by turning clockwise.

•  Gator 5000/6000/8000/9000: Stroke length can be be adjusted continuously from 9 – 15 mm (factory mode: 15 mm).

7.5 Mounting

7.5.1 Drill pattern Gator 2000/3000/3010/5000/6000/8000/9000

17,3

41

66,5

Gator 2000: Middle axis of nut of the electronic lock congruent with

middle of the input unit (Gator RO)/knob input unit (Gator R/DR)

Gator 2000: drill-hole not necessary

• For fixing the electronic lock 4 threaded holes M6 with depth min. 6 mm (or a comparable inch thread) have to be drilled 

into the safe door.

• Gator 2000: Lead connection cable through the lock and adjust the electronic lock on the connection axis.
•  Fixing the lock with screws M6 or a comparable inch thread. Length and material application of the screw has to be selected 

such as a secure long-term stability is guaranteed. 

• Turn the screws with a maximum turning force of 3.5 – 5 Nm.
•  Independent loosening of the screws has to be avoided. Recommendation: put lock washers underneath the screw’s head.
• After the installation the lock’s bolt may not be loaded.
• Mind sufficient slackness of the locking point.

Summary of Contents for GATOR 2000

Page 1: ..._________________________________ 6 5 Installation input unit Gator FS_____________________________________________________ 7 6 Installation input unit Gator F DF R DR_________________________________...

Page 2: ...point out that this installation instruction is part of the VdS certification and non compliance leads to the loss of this certification By opening the lock cover warranty of the manufacturer will be...

Page 3: ...or RO Fixing ring for input unit Cylinder screws M4 x 10 Connection axis for turnable input unit Input unit Connection cable 3 3 Panel hole Gator RO turnable 3 3 1 Spindle square 3 3 2 Spindle round T...

Page 4: ...RO 4 x Fixing position for M4 Gator RO fixed opening for cable Drill hole min 8 mm max 11 4 mm for connection cable Gator RO turnable Hole center congruent with middle axis of nut of the electronic lo...

Page 5: ...lock boltwork and insert grub screw M3 x 6 or arrest pin 3 5 4 Cable guidance Gator RO turnable 3 5 5 Plug position Gator RO Connection axis Audit Lock Gator PowerAdapt Gator RO turnable Lead connecti...

Page 6: ...and has to be lead well accessible 4 Installation input unit Gator FL 4 1 Input unit Gator FL fixing on the inside 4 1 2 Input unit Gator FL fixing on the front 4 1 3 Dimensions Gator FL Emergency po...

Page 7: ...o be drilled into the safe door From the front 2 threaded holes M5 with sufficient depth and 1 through hole opening for cable have to be drilled into the safe door Fix the input unit with the enclosed...

Page 8: ...ut unit Gator R DR iButton reader optional iButton reader optional 6 1 2 Dimensions Gator F DF 6 1 3 Dimensions Gator R DR 14 Kabeldurchlass Opening 6 2 Axis length calculation input unit Gator R DR 6...

Page 9: ...ews M4 From the front 4 threaded holes M4 with sufficient depth and 1 through hole opening for cable connection axis have to be drilled into the safe door Fix the input unit with the enclosed 4 screws...

Page 10: ...setting between the bus channels The bus channel A and bus channel B of he input units can change in the foll wing way Arrow left select bus channel A Arrow right select bus channel B 6 3 5 Battery c...

Page 11: ...Power supply via adapter Factory mode Slide DIP switch at the back of the battery compartment into illustrated position Insert 3 x 1 5 AA Alkaline batteries Slide DIP switch at the back of the battery...

Page 12: ...t a security and functional test of the electronic lock For safety reasons it is not allowed to locate the electronic lock in the area where openings are except Gator 2000 The electronic lock has to b...

Page 13: ...m 9 15 mm factory mode 15 mm 7 5 Mounting 7 5 1 Drill pattern Gator 2000 3000 3010 5000 6000 8000 9000 17 3 41 66 5 Gator 2000 Middle axis of nut of the electronic lock congruent with middle of the in...

Page 14: ...ator 6000 8000 9000 GatorSignal plus 8 pin Input unit 4 pin Gator PowerAdapt GatorSignal plus 8 pin Redundanz 4 pin nput unit Gator PowerAdapt 4 pin Plug in the connection cable of the input unit in p...

Page 15: ...C Bus address lock 00 01 02 8 3 Adjusting bus addresses input units Gator RO FL FS F DF R DR The input unit must be in full working order The bus addresses of the input unit Bus address are factory ad...

Page 16: ...ency power supply optional insert 1 x 9V block Alkaline 9 1 Gator PowerAdapt 9 1 1 Plug position PowerAdapt 9 1 2 Drill pattern Gator PowerAdapt Connection cable Adapter 9V 78 41 36 47 5 Gator PowerAd...

Page 17: ...m Power Adapt Power Adapt optional bus cables for redundancy Attention When there are more than 3 locks per system we recommend to use further more external power supplies This would need to be verifi...

Page 18: ...l bus cables for redundancy Attention When there are more than 3 locks per system we recommend to use further more external power supplies This would need to be verified individually Redundancy system...

Page 19: ...in reverse order Gator 3000 3010 The lock s bolt opens automatically has to happen easily The lock is opened Turn the handle within 20 seconds into opening position Turn the handle into locking positi...

Page 20: ...20 Installation instructions Gator Rel 1 2...

Reviews: